Special transformers (ester oil, explosion-proof DPRS/TPRS, SF6 gas-insulated, SVC, phase-shifting, HVDC, traction, furnace, marine, mobile)
The manufacturer produces transformers for special operating conditions. The range includes fire-safe units with ester oil and a fire point above 300 °C, explosion-proof ones with DPRS/TPRS systems and SF6 gas-insulated ones for underground substations.
- Ester oil
- fire point above 300 °C
- Explosion protection
- DPRS/TPRS systems
- SF6 gas-insulated
- SF6, water/air cooling
- Other types
- SVC, phase-shifting, HVDC converter, traction (Scott connection), furnace, marine, mobile
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
SF6 gas-insulated transformers use SF6 insulation and are produced with water or air cooling. For power systems there are transformers for SVC, phase-shifting and converter transformers for HVDC. Traction transformers are supplied for electrified railways, including the Scott connection. Separate designs are made for furnaces, offshore platforms and ships, as well as mobile transformers.
Technical specifications
| Ester oil | fire point above 300 °C |
|---|---|
| Explosion protection | DPRS/TPRS systems |
| SF6 gas-insulated | SF6, water/air cooling |
| Other types | SVC, phase-shifting, HVDC converter, traction (Scott connection), furnace, marine, mobile |
Replacement for
ТДН/ТРДН-…/110 (general type); ester-oil, explosion-proof, SF6 gas-insulated and phase-shifting types have no direct analog
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Special transformers (ester oil, explosion-proof DPRS/TPRS, SF6 gas-insulated, SVC, phase-shifting, HVDC, traction, furnace, marine, mobile). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 23 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What is the fire point of ester-oil transformers?
Above 300 °C, so these transformers are classed as fire-safe designs.
What explosion protection systems are used?
Explosion-proof transformers are equipped with DPRS/TPRS systems.
How are SF6 gas-insulated transformers cooled?
SF6 insulation, water or air cooling. Such units are installed at underground substations.
Similar equipment from other manufacturers