Special transformers (ester-oil, SF6 gas-insulated, mobile, phase-shifting, Scott, furnace, for STATCOM)
Special transformers from the manufacturer: ester-oil, SF6 gas-insulated, mobile, phase-shifting, for STATCOM, Scott and furnace types. Scott transformers are available in 30/40, 45/60, 60/80 and 90/120 MVA ratings.
- Types
- ester-oil, SF6 gas-insulated, mobile, phase-shifting, for STATCOM, Scott, furnace
- Ester oil
- fire safety class K (above 300 °C)
- SF6 gas-insulated
- SF6 stable up to 500 °C, water cooling
- Scott transformers
- 30/40, 45/60, 60/80, 90/120 MVA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Eco-friendly transformers are filled with biodegradable ester oil of fire safety class K, with a temperature above 300 °C. SF6 gas-insulated units go to urban and underground substations; SF6 is stable up to 500 °C, cooling is by water. Phase-shifting transformers are used to control power flows between networks. Scott transformers are applied in traction networks, and furnace transformers work on metallurgical furnaces.
Technical specifications
| Types | ester-oil, SF6 gas-insulated, mobile, phase-shifting, for STATCOM, Scott, furnace |
|---|---|
| Ester oil | fire safety class K (above 300 °C) |
| SF6 gas-insulated | SF6 stable up to 500 °C, water cooling |
| Scott transformers | 30/40, 45/60, 60/80, 90/120 MVA |
Replacement for
furnace types ЭТЦП, ЭТЦПК; phase-shifting, SF6 gas-insulated, Scott and ester-oil types have no direct analog
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Special transformers (ester-oil, SF6 gas-insulated, mobile, phase-shifting, Scott, furnace, for STATCOM). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 23 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What fire safety class do the manufacturer's ester-oil transformers have?
Class K, with a temperature above 300 °C. The oil is biodegradable.
Where are the manufacturer's SF6 gas-insulated transformers used?
At urban and underground substations. SF6 is stable up to 500 °C and cooling is by water.
What ratings are available for Scott transformers?
30/40, 45/60, 60/80 and 90/120 MVA for traction networks.