RY15 / RV15 / CK15 / C15F — 15 kV instrument transformers, American design (CSA/IEEE)

The 15 kV American Design group comprises dry-type instrument transformers with cast insulation for indoor installation in 15 kV class networks under CSA and IEEE standards. It includes the RY15 voltage transformer, the two-pole RV15, the CK15 current transformer and the C15F combined unit. They are used in switchgear and pad-mounted equipment of 15 kV.

RY15
phase-to-earth VT, 15/36/110 kV, up to 15,000/√3 V, thermal burden up to 1750 VA, 50 kg
RV15
phase-to-phase VT, 15/36/110 kV, up to 15,000 V, with primary fuse holders (0.5 or 1 A), up to 1750 VA, 50 kg, CSA LR 109295
CK15
CT, 15/36/110 kV, up to 1200 A, Ith up to 50 kA for 1 s, 20 kg
C15F
combined CT+VT, 25/50/125 kV, up to 200 A, 16 kA for 1 s, 200 A bushing per IEEE 386, 45 kg

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The group is designed for North American markets and projects under CSA and IEEE standards. The design, accuracy classes and burden designations are typical of these markets, and the networks are of the 15 kV class. All products are dry-type with cast insulation, for indoor installation. Standards are IEC 61869-2/-3/-4, CSA C61869-2/-3/-4 and IEEE C57.13. Frequency is 50/60 Hz.

The RY15 is a single-pole voltage transformer (phase-to-earth) with insulation up to 15/36/110 kV, primary voltage up to 15,000/√3 V, thermal burden up to 1750 VA and a mass of about 50 kg. The RV15 is a two-pole (phase-to-phase) voltage transformer with primary fuse clips, insulation up to 15/36/110 kV, primary voltage up to 15,000 V and a voltage factor of up to 1.2 Un continuously. Burdens are up to 75 VA in class 0.2, 200 VA in class 0.5 and 500 VA in class 1, under CSA/IEEE up to 0.3WXYZ, thermal burden up to 1750 VA, mass 50 kg. A primary fuse of 0.5 or 1 A can be fitted as an option. It has CSA qualification (approval LR 109295).

The CK15 is a compact indoor current transformer with insulation up to 15/36/110 kV, primary current up to 1200 A, short-time thermal current up to 50 kA for 1 s, dynamic current up to 2.5 Ith and one core. A dual transformation ratio is obtained by tapping the secondary winding. Classes are IEC 0.1–PX and CSA 0.15–10L, with CSA qualification and a mass of about 20 kg. The C15F is a combined current and voltage transformer (one CT and one phase-to-earth VT in a common cast housing), fully earthed. It has a 200 A primary connection per IEEE 386 (plug-in cable bushings), insulation up to 25/50/125 kV, primary current up to 200 A, short-time thermal current up to 16 kA for 1 s, a temperature range of −25…+50 °C and a mass of about 45 kg.

Accuracy classes of the VTs are 0.1–6P under IEC, 0.15–1.2, 3P and 6P under CSA, and 0.15–1.2 under IEEE. The transformers are used in switchgear and pad-mounted equipment of 15 kV and at primary metering points of network companies.

Technical specifications

RY15phase-to-earth VT, 15/36/110 kV, up to 15,000/√3 V, thermal burden up to 1750 VA, 50 kg
RV15phase-to-phase VT, 15/36/110 kV, up to 15,000 V, with primary fuse holders (0.5 or 1 A), up to 1750 VA, 50 kg, CSA LR 109295
CK15CT, 15/36/110 kV, up to 1200 A, Ith up to 50 kA for 1 s, 20 kg
C15Fcombined CT+VT, 25/50/125 kV, up to 200 A, 16 kA for 1 s, 200 A bushing per IEEE 386, 45 kg
ClassesIEC 0.1–6P / 5P / 10P / PX; CSA 0.15–1.2; IEEE 0.15–1.2
StandardsIEC 61869-2/-3/-4, CSA C61869, IEEE C57.13

Replacement for

ЗНОЛ.06-6, ЗНОЛ.06-10, ЗНОЛП-10, НОЛ.08-10, НАМИ-10, НТМИ-10; ТОЛ-10, ТЛО-10, ТПЛ-10, ТЛК-10, ТЛМ-10, ТПОЛ-10; no direct analogue under IEEE/CSA

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

RY15 / RV15 / CK15 / C15F — 15 kV instrument transformers, American design (CSA/IEEE). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What insulation and current does the CK15 current transformer have?

The CK15 has insulation up to 15/36/110 kV, primary current up to 1200 A and short-time thermal current up to 50 kA for 1 s.

What function does the C15F perform?

The C15F combines one CT and one phase-to-earth VT in a common cast housing. Insulation is up to 25/50/125 kV, and the primary connection is rated 200 A per IEEE 386.

Is the RV15 CSA qualified?

Yes, the RV15 is CSA qualified (approval LR 109295). It is two-pole, with insulation of 15/36/110 kV and thermal burden up to 1750 VA.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides