Rectifier transformers, regulating autotransformers, saturable reactors and interphase transformers
Rectifier transformers, together with regulating autotransformers, saturable reactors and interphase transformers, supply AC/DC and AC/AC converters. A built example has 50 MVA, 26.4 kV / 610 V, vector group D d0 y1, OFWF cooling. They are used at aluminium smelters, in electrolysis, graphitising furnaces and traction substations.
- Example
- 50 MVA, 26.4 kV / 610 V, D d0 y1, OFWF
- Applications
- electrolysis, aluminium smelters, DC arc furnaces, traction substations, graphitising furnaces, frequency converters
- Package
- rectifier transformer, regulating (auto)transformer, saturable reactors, interphase transformers
- Cooling
- OFWF (example)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Rectifier transformers link the supply grid with AC/DC and AC/AC converters and bring the input parameters to the values needed for rectification and regulation of the output current. The duty of such transformers is characterised by high currents and a distorted waveform, so the windings, magnetic core and cooling are calculated with harmonics taken into account.
The manufacturer holds a prominent position in supplying rectifier transformers for electrolysis processes, aluminium smelters and other metal refining processes, for DC furnaces in electrometallurgy and for DC traction. Typical applications are DC arc furnaces, electrolysis, aluminium production, graphitising furnaces, traction substations, metal refining and frequency converters for variable-speed electric drives.
A rectifier transformer is often supplied with regulating transformers or autotransformers, saturable reactors and interphase (balancing) transformers. All of them are part of the manufacturer's portfolio. The transformer works for long periods under a large constant load, for example in an electrolysis shop where the line almost never stops, so winding heating and harmonic withstand come first. The regulating autotransformer changes the voltage at the rectifier input, the saturable reactor smoothly corrects the current, and the interphase transformer equalises the load between parallel valve groups. An example of parameters is a new rectifier transformer of 50 MVA, 26.4 kV / 610 V, vector group D d0 y1, OFWF cooling for a US metals producer. At the same site an ester retrofill of a 48 MVA, 26.4 kV / 561 V transformer was carried out.
The insulating liquid may be mineral oil or ester, which reduces the fire load. The manufacturer's design department works closely with production to adapt the transformers to the development of consumers' technologies. The plants have their own test benches for routine, type and special tests to IEC or IEEE. The management system is certified to ISO 9001 by IMQ. Over the last ten years more than one thousand transformers have been made. The manufacturer also operates through subsidiaries in the USA and India, and more than 60 % of turnover is from export. Applications are electrochemistry and electrometallurgy, metallurgical works, and traction substations of metro and railways.
Technical specifications
| Example | 50 MVA, 26.4 kV / 610 V, D d0 y1, OFWF |
|---|---|
| Applications | electrolysis, aluminium smelters, DC arc furnaces, traction substations, graphitising furnaces, frequency converters |
| Package | rectifier transformer, regulating (auto)transformer, saturable reactors, interphase transformers |
| Cooling | OFWF (example) |
| Insulating liquid | mineral oil or ester |
Replacement for
ТДНП, ТМНП, ТДП, ТРДП (rectifier/converter 6–110 kV); regulating autotransformers and saturable reactors, general type
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Rectifier transformers, regulating autotransformers, saturable reactors and interphase transformers. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What parameters does the built rectifier transformer have?
The new transformer for a US metals producer has 50 MVA, 26.4 kV / 610 V, vector group D d0 y1 and OFWF cooling.
What does the rectification package consist of?
A rectifier transformer, a regulating transformer or autotransformer, saturable reactors and interphase transformers.
Which processes are rectifier transformers intended for?
For electrolysis, aluminium smelters, metal refining, DC arc furnaces, graphitising furnaces and traction substations of metro and railways.
Similar equipment from other manufacturers