Power transformers 5–300 MVA up to 400 kV and autotransformers up to 500 MVA

Power transformers from 5 to 300 MVA for the 33, 66, 132, 275 and 400 kV classes and liquid-immersed autotransformers up to 500 MVA. Each unit is designed for the site, and designs for iDNOs are available. Used in high-voltage networks, combined-cycle plants and BESS substations.

Rating
5–300 MVA (two-winding and three-winding); autotransformers up to 500 MVA
Voltage
33, 66, 132, 275, 400 kV (non-standard on request)
Vector groups
Dyn11, Dyn1 (up to 132 kV), YNd11, YNd1
Cooling
ONAN/ONAF, CER; tank-mounted radiators or separate coolers

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Two-winding and three-winding power transformers rated from 5 to 300 MVA and autotransformers up to 500 MVA are made for the voltage classes 400, 275, 132, 66 and 33 kV; non-standard voltages are made on request. The units, including extra-high-voltage ones, meet the requirements of Ecodesign Tier 2 (Tier 1 only by an agreed exception). The insulation is liquid, mineral oil up to 400 kV, and manufacture follows IEC, BS and other international standards.

Each transformer is designed for a specific site. Typical vector groups are Dyn11, Dyn1 (up to 132 kV), YNd11 and YNd1. Cooling is ONAN/ONAF, a continuous emergency rating (CER) and forced air cooling with fans are possible. Radiators are tank-mounted or separate cooler banks, and voltage is regulated by an OLTC.

For independent distribution network operators (iDNOs), designs up to 120 MVA at 33, 66 and 132 kV have been produced to the design specifications of British DNOs, with ONAN/ONAF/CER cooling and an OLTC. They are suitable for schemes where, if one transformer fails or is under repair, the second takes the whole load of the site. Completed projects include a 60 MVA 132/33 kV transformer for the Osbaldwick BESS (50 MW), connected to Northern Powergrid. In 2022 a 140 MVA transformer became the basis of the first connection of a solar farm to the transmission network in the UK.

Auxiliary and earthing transformers are supplied together with the main unit. The manufacturer performs factory (FAT) and site (SAT) tests and has its own project managers and installation engineers (rigging, assembly, oil filling and filtration, cable work). The warranty is 24 months from shipment, and an extended one is possible. Every power transformer undergoes routine acceptance tests at the factory according to the relevant parts of IEC 60076; type tests are performed on request for an additional fee. Site tests (SAT) check the operation of the unit in the actual scheme of the facility.

Production is in Leeds (UK) and Chennai (India). The site of over 5500 m² has three production bays by transformer type and size, two test stands and two paint booths, and the engineering team in the UK adapts designs to project requirements. Typical applications are high-voltage power transmission, energy storage systems (BESS), combined-cycle generation and connection of renewables.

Technical specifications

Rating5–300 MVA (two-winding and three-winding); autotransformers up to 500 MVA
Voltage33, 66, 132, 275, 400 kV (non-standard on request)
Vector groupsDyn11, Dyn1 (up to 132 kV), YNd11, YNd1
CoolingONAN/ONAF, CER; tank-mounted radiators or separate coolers
RegulationOLTC
Insulationliquid, mineral oil up to 400 kV
EfficiencyEcodesign Tier 2 (Tier 1 by exception)
Warranty24 months from shipment
StandardsIEC, BS, DNO specifications (UK)

Replacement for

ТДН-16000/110, ТРДН-40000/110, ТРДЦН-63000/110, ТРДЦН-160000/220, АТДЦТН-200000/220/110, АТДЦТН-200000/330/110

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Power transformers 5–300 MVA up to 400 kV and autotransformers up to 500 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What rating and voltage class do the power transformers have?

Two-winding and three-winding units are made from 5 to 300 MVA, autotransformers up to 500 MVA. The voltage classes are 33, 66, 132, 275 and 400 kV, with non-standard values on request.

Which vector groups and cooling methods are available?

Dyn11, Dyn1 (up to 132 kV), YNd11 and YNd1. Cooling is ONAN/ONAF, also CER; radiators are tank-mounted or separate cooler banks.

Are there versions for iDNOs and BESS substations?

For iDNOs there are designs up to 120 MVA at 33, 66 and 132 kV to the specifications of British DNOs. A 60 MVA 132/33 kV transformer was built for the Osbaldwick BESS (50 MW).

Similar equipment from other manufacturers