Phase-shifting transformers (PST)
Phase-shifting transformers (PST) control active power flows in AC networks. They are installed to relieve overloaded lines and cross-border interconnections. The manufacturer has more than 50 years of experience in PST design.
- Design
- two-core (high ratings) or single-core up to 230 kV
- Principle
- indirect scheme with shunt (regulating) and series units
- Insulation
- among other options, ester liquid
- Experience
- more than 50 years of PST design
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
For high ratings a two-core design is used, while the single-core version is made up to 230 kV. The principle is indirect, with shunt (regulating) and series units. Insulation can be, among other options, an ester liquid. Controlled power flow reduces loop flows and makes it possible to use the available network capacity more fully.
Technical specifications
| Design | two-core (high ratings) or single-core up to 230 kV |
|---|---|
| Principle | indirect scheme with shunt (regulating) and series units |
| Insulation | among other options, ester liquid |
| Experience | more than 50 years of PST design |
Replacement for
no direct analogue (phase-shifting transformers were not series-produced); closest are ЛТДН, ЛТМН (line regulating), ВРТДНУ (voltage-adding)
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Phase-shifting transformers (PST). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 23 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Why install a phase-shifting transformer?
To control active power flows and to relieve overloaded lines and cross-border interconnections.
Up to what voltage is the single-core design made?
Up to 230 kV. For high ratings a two-core design is used.
Is ester liquid insulation possible?
Yes, PSTs are made, among other options, with ester liquid.
Similar equipment from other manufacturers