International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

OTF transformer for arc and ladle furnaces up to 120 MVA

OTF, a furnace transformer rated up to 120 MVA with an insulation level up to LI 350 kV for electric arc, ladle and ore-reduction furnaces. Secondary current is up to 90 kA for steel and up to 160 kA for ferroalloys.

Rating
up to 120 MVA
Insulation level
up to LI 350 kV
Secondary current
up to 90 kA (steel), up to 160 kA (ferroalloys)
Furnace types
AC and DC EAF, ladle, ore-reduction

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The transformer is designed for the heavy duty of furnace loads with current surges and overvoltages. It works with AC and DC EAFs, ladle furnaces and ore-reduction furnaces. Voltage is regulated directly by HV taps, through a booster transformer or through an autotransformer. The regulation scheme is chosen to suit the furnace rating and the required secondary voltage range.

Technical specifications

Ratingup to 120 MVA
Insulation levelup to LI 350 kV
Secondary currentup to 90 kA (steel), up to 160 kA (ferroalloys)
Furnace typesAC and DC EAF, ladle, ore-reduction
Regulationdirect by HV taps, booster transformer, autotransformer

Replacement for

ЭТЦП-…/10–35, ЭТЦПК-…/35, ЭТМПК-…/10, ЭОЦНК (single-phase furnace)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

OTF transformer for arc and ladle furnaces up to 120 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 80
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 11 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What secondary current does the OTF furnace transformer deliver?

Up to 90 kA for steelmaking furnaces and up to 160 kA for ferroalloy furnaces.

Which furnaces is the OTF suitable for?

AC and DC EAFs, ladle furnaces and ore-reduction furnaces, with a transformer rating up to 120 MVA.

How is the secondary voltage of the furnace transformer regulated?

Directly by HV taps, through a booster transformer or an autotransformer.