International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ICR 260 / ICR 330 — HV inrush current limiting reactors for capacitor banks up to 36 kV

ICR 260 and ICR 330 are air-core, resin-encapsulated inrush current limiting reactors for rated currents from 50 to 250 A. They are connected in series with a high-voltage capacitor bank to limit the inrush current on switching. They are used in fixed and automatic banks of 6–36 kV.

Type
air-core, resin-encapsulated
Rated current
ICR 260: 50–175 A; ICR 330: 60–250 A
Inductance
ICR 260: 350–30 μH; ICR 330: 450–30 μH
Imax
1.43 In

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

When a capacitor bank is switched on, especially in parallel with banks that are already in operation, inrush currents arise that exceed the rated current many times over. They are dangerous for capacitors, contactors and circuit breakers. A reactor connected in series with the bank limits the amplitude and the steepness of this transient current. It is fitted when several banks or stages operate in parallel, and also when replacing reactors in existing reactive power compensation installations at substations and industrial plants.

The reactor is an air-core type, without a steel core, and is fully encapsulated in resin. As a result the inductance is linear, there is no saturation, and external influences do not affect it. Versions are available for indoor and outdoor installation. The insulation thermal class is B and the own insulation level is 12 kV (28/75 kV). For networks above 12 kV and up to 36 kV the reactor is mounted on 17.5, 24 or 36 kV indoor or outdoor support insulators through an adapter. Fixing is by M12 or M12/M16 inserts. Without a steel core the current does not saturate the reactor even during inrush.

The maximum continuous current is 1.43 In. The rated short-time current is 43 In for 1 s, and another kA/s value is made to order. The dynamic current is 2.5 Ith. The ICR 260 range has a diameter of 260 mm and a height of 390 mm. Rated currents of 50, 60, 100, 125 and 175 A correspond to inductances of 350, 250, 100, 50 and 30 μH, with a mass of 13–16 kg. The ICR 330 reactor is larger, with a diameter of 330 mm and a height of 470 mm. Its rated currents of 60, 75, 90, 125, 200 and 250 A correspond to inductances of 450, 350, 250, 100, 50 and 30 μH, with a mass of 20–26 kg.

There are two ranges, so the reactor is selected by the rated current of the bank and the required inductance. The reactors comply with the IEC 60076-6:2007 standard. Other powers, voltages and frequencies are made on request. Methods for selecting a reactor for a single bank and for banks switched in parallel are given in the manufacturer's catalogue.

Technical specifications

Typeair-core, resin-encapsulated
Rated currentICR 260: 50–175 A; ICR 330: 60–250 A
InductanceICR 260: 350–30 μH; ICR 330: 450–30 μH
Imax1.43 In
Short-time current43 In / 1 s (other kA/s to order)
Dynamic current2.5 Ith
Insulation level12 kV (28/75 kV); with support insulators 17.5/24/36 kV
Thermal classB
Mass13–26 kg
StandardIEC 60076-6:2007

Replacement for

inrush current limiting reactors for 6–35 kV capacitor banks — РБ/РТОС (general type), ФРОС

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

ICR 260 / ICR 330 — HV inrush current limiting reactors for capacitor banks up to 36 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What rated currents and inductance does the ICR 260 have?

The ICR 260 is made for 50, 60, 100, 125 and 175 A with inductances of 350, 250, 100, 50 and 30 μH respectively. Diameter is 260 mm, height 390 mm and mass 13–16 kg.

What is the insulation level and how is the reactor installed in networks up to 36 kV?

The own insulation level is 12 kV (28/75 kV). For networks above 12 kV and up to 36 kV the reactor is mounted on 17.5, 24 or 36 kV support insulators through an adapter.

Is there an outdoor version and to which standard are the reactors made?

Yes, versions for indoor and outdoor installation are available, with insulation thermal class B. The reactors comply with IEC 60076-6:2007.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides