International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Furnace transformers for AC and DC arc furnaces

Furnace transformers for arc steelmaking and ferroalloy furnaces. For AC furnaces they are made for voltage over 1500 V and current over 160 kA, for DC furnaces for over 1200 V and over 100 kA.

AC furnaces
over 1500 V, over 160 kA
DC furnaces
over 1200 V, over 100 kA
Application
steel (long arc), ferroalloys (short arc)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The transformers feed AC arc furnaces and also DC furnaces as part of rectifier installations. In steelmaking the furnace operates with a long arc, in ferroalloy production with a short arc. The transformer is selected for the mode of the specific furnace and its working current.

Technical specifications

AC furnacesover 1500 V, over 160 kA
DC furnacesover 1200 V, over 100 kA
Applicationsteel (long arc), ferroalloys (short arc)

Replacement for

ЭТЦП-…/10–35, ЭТЦПК-…/35, ЭТМПК-…/10, ЭОЦНК (single-phase furnace)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Furnace transformers for AC and DC arc furnaces. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 41
8504 23 00 45
8504 23 00 80
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 11 00
8504 23 12 00
8504 23 13 00
8504 23 21 00
8504 23 29 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What currents do the furnace transformers withstand?

Over 160 kA for AC furnaces and over 100 kA for DC furnaces.

Are they suitable for DC furnaces?

Yes, as part of a rectifier installation, at voltage over 1200 V and current over 100 kA.

Which industries are they used in?

For steel melting in long-arc furnaces and for ferroalloys in short-arc furnaces.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides