International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

COMTRAXX® COM465DP condition monitor with PROFIBUS DP and Ethernet gateway, AC/DC 24…240 V

The COMTRAXX® COM465DP is a condition monitor with a built-in gateway to PROFIBUS DP and Ethernet-TCP/IP networks. It speaks Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT and OPC UA. Supply AC/DC 24…240 V.

Type
Condition monitor with integrated gateway
Networks
PROFIBUS DP, Ethernet-TCP/IP
Protocols
PROFIBUS DP, Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT, BCOM, OPC UA
Interfaces
RS-485, Ethernet, USB

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A condition monitor and a protocol gateway in one housing: the COMTRAXX® COM465DP connects the manufacturer's monitoring devices to PROFIBUS DP and Ethernet-TCP/IP networks. Alarms, measured values and device states are converted into protocols such as Modbus TCP, SNMP and HTTP. That couples them to standard networks and makes them visible in a web browser.

On the device side it works with the BMS bus and the BCOM interface; the unit itself has RS-485, Ethernet and USB. Supported protocols are PROFIBUS DP, Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT, BCOM and OPC UA. The device's own parameters are set in a web interface, and remote access runs over Ethernet. A history memory and configurable data loggers are included, and time synchronisation covers the assigned devices.

Function modules A to F extend the base unit. Module A adds individual text messages, device failure monitoring and e-mail. Module B provides data over Modbus TCP, Modbus RTU, SNMP and PROFINET. Module C sets parameters on all integrated devices and keeps device backups. Module D is a visualisation application, module E adds virtual devices, and module F integrates third-party devices. External applications such as PLCs can read the data without extra PC software.

The supply is AC/DC 24…240 V with a consumption of no more than 6,5 VA / 4 W. Rated voltage is AC 250 V, rated impulse withstand voltage 4 kV, overvoltage category III and pollution degree 3. The housing measures 62,9 x 107,5 x 48,5 mm.

Mounting is on a DIN rail or with screws (3 x M4), and the supply needs a 6 A fuse. The variant for PROFIBUS DP and Ethernet is COM465DP-230V.

Technical specifications

TypeCondition monitor with integrated gateway
NetworksPROFIBUS DP, Ethernet-TCP/IP
ProtocolsPROFIBUS DP, Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT, BCOM, OPC UA
InterfacesRS-485, Ethernet, USB
Supply voltage UsAC/DC 24…240 V
FrequencyDC, 50…60 Hz
Power consumption≤ 6,5 VA / ≤ 4 W
Rated voltageAC 250 V
Rated impulse withstand voltage4 kV
Overvoltage categoryIII
Pollution degree3
Dimensions62,9 x 107,5 x 48,5 mm
MountingDIN rail, screws (3 x M4)

Part numbers

Show all part numbers (2)

B95061060, modules B75061011…B75061016

How it compares with similar models

ParameterCOMTRAXX® COM465DP condition monitor with PROFIBUS DP and Ethernet gateway, AC/DC 24…240 VCOMTRAXX® COM463BC gateway between BCOM and an external BMS, AC/DC 24…240 VCOMTRAXX® COM465IP condition monitor with Ethernet gateway, AC/DC 24…240 VCOMTRAXX® EDGE500IP condition monitor with gateway, 2 x Ethernet, RS-485, DC 24 V
TypeCondition monitor with integrated gateway—Condition monitor with integrated gatewayCondition monitor with gateway functions
ProtocolsPROFIBUS DP, Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT, BCOM, OPC UA—Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT, BCOMModbus TCP, Modbus RTU, SNMP, MQTT, PROFINET, OPC UA, HTTP, HTTPS, DHCP, NTP, SMTP, BCOM
InterfacesRS-485, Ethernet, USBRS-485, EthernetRS-485, Ethernet2 x Ethernet, RS-485, USB
Rated voltageAC 250 VAC 250 V—AC 50 V

Request a price and lead time

COMTRAXX® COM465DP condition monitor with PROFIBUS DP and Ethernet gateway, AC/DC 24…240 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which protocols does the COM465DP support?

PROFIBUS DP, Modbus TCP, Modbus RTU, SNMP, PROFINET, MQTT, BCOM and OPC UA. Data over Modbus TCP, Modbus RTU, SNMP and PROFINET is enabled by module B.

What are function modules A to F for?

They extend the base unit. Module C, for example, sets parameters on integrated devices and keeps their backups, and module F integrates third-party devices.

How does the COM465DP differ from the COM465IP?

The DP version connects to PROFIBUS DP and Ethernet, while the COM465IP works with Ethernet only.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides