International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

COMTRAXX® CP907-I condition monitor with 7" display and gateway, DC 24 V

The COMTRAXX® CP907-I is a condition monitor with a 7" touch display (800 x 480) and a built-in gateway. It speaks Modbus RTU, Modbus TCP, PROFINET, OPC UA, MQTT and SNMP. Supply DC 24 V or PoE DC 48 V, IP54 at the front.

Type
Condition monitor with display and gateway
Display
7" (17.6 cm), TFT, touch
Resolution
800 x 480
Interfaces
RS-485, Ethernet, USB

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Display and gateway sit in one housing in the COMTRAXX® CP907-I. The condition monitor collects data from the manufacturer's devices and from third-party equipment over the BMS bus, Modbus RTU, Modbus TCP and Ethernet. Statuses and alarms are shown on the built-in display or in a web browser, with access over LAN, WAN or the Internet, including remote diagnosis and maintenance.

The TFT display measures 7" (17.6 cm) with 800 x 480 pixels and tempered glass. The gateway supports Modbus RTU, Modbus TCP, PROFINET, OPC UA, MQTT and SNMP, and the unit offers RS-485, Ethernet and USB. It has no fan and runs silently.

The nominal supply is DC 24 V SELV/PELV (tolerance ±20 %), or PoE at DC 48 V SELV/PELV (–25…+15 %). Typical consumption is below 15 W. Rated voltage for Ethernet is 50 V and rated impulse voltage 800 V. The front is IP54, the enclosure IP20, and the flammability class is UL 94V-0.

Operating temperature is –10…+55 °C (–10…+50 °C for UL), relative humidity up to 98 % at 25 °C and altitude up to 2000 m above sea level. The device measures 226 x 144 x 78 mm and weighs 1.1 kg. It is designed to IEC 60664-1, IEC 61326-1 and IEC 60947-5-1, and a UL approval applies for UL applications.

Typical locations are manufacturing plants, data centres and control stations. It is installed in a flush-mounting enclosure, in a control cabinet door with a mounting frame, or in a surface-mounted enclosure. The complete device B95061031 has a 7" display, DC 24 V, a flush-mounting enclosure and white glass.

Technical specifications

TypeCondition monitor with display and gateway
Display7" (17.6 cm), TFT, touch
Resolution800 x 480
InterfacesRS-485, Ethernet, USB
ProtocolsModbus RTU, Modbus TCP, PROFINET, OPC UA, MQTT, SNMP
Supply voltageDC 24 V SELV/PELV, ±20 %
PoE supplyDC 48 V SELV/PELV, –25…+15 %
Power consumption, typical< 15 W
Rated voltage (Ethernet)50 V
Rated impulse voltage800 V
Degree of protection, front / enclosureIP54 / IP20
Operating temperature–10…+55 °C (UL –10…+50 °C)
Relative humidity≤ 98 % at 25 °C
Operating altitude≤ 2000 m
Flammability classUL 94V-0
Dimensions (W x H x D)226 x 144 x 78 mm
Weight1.1 kg

Part numbers

Show all part numbers (7)

B95061031, B95100140, B95061915, B95061912, B95061910, B95061911, B94053111

How it compares with similar models

ParameterCOMTRAXX® CP907-I condition monitor with 7" display and gateway, DC 24 VCOMTRAXX® EDGE500IP condition monitor with gateway, 2 x Ethernet, RS-485, DC 24 VCOMTRAXX® RCP115 15.6" industrial touch panel, Full HD, DC 24 VCOMTRAXX® CP9xx touch control panels, 7", 15.6" and 24" displays, IP54
TypeCondition monitor with display and gatewayCondition monitor with gateway functionsIndustrial touch panelRemote alarm indicators and operator panels, touch TFT
Resolution800 x 480—1920 x 1080 pixels (Full HD, 16:9)800 x 480 (7"), 1280 x 720 (15.6"), 1280 x 720 or 1920 x 1080 (24")
InterfacesRS-485, Ethernet, USB2 x Ethernet, RS-485, USBEthernet 10/100/1000 Mbps, USB 2.0 HostRS-485, Ethernet, USB, 3.5 mm audio jack
ProtocolsModbus RTU, Modbus TCP, PROFINET, OPC UA, MQTT, SNMPModbus TCP, Modbus RTU, SNMP, MQTT, PROFINET, OPC UA, HTTP, HTTPS, DHCP, NTP, SMTP, BCOM—Modbus TCP, Modbus RTU, SNMP, MQTT, PROFINET, EtherNet/IP, OPC UA, PROFIBUS DP, KNX, DeviceNet, BACnet
Supply voltageDC 24 V SELV/PELV, ±20 %—DC 24 VCP907 DC 24 V SELV/PELV; CP915 and CP924 AC 100…240 V
Operating temperature–10…+55 °C (UL –10…+50 °C)–25…+55 °C0…+50 °CCP907 –10…+55 °C; CP915 and CP924 –10…+50 °C

Request a price and lead time

COMTRAXX® CP907-I condition monitor with 7" display and gateway, DC 24 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What are the display specifications of the CP907-I?

A 7" (17.6 cm) TFT touch display with 800 x 480 pixels and tempered glass.

How is the CP907-I powered?

From DC 24 V SELV/PELV (±20 %) or by PoE at DC 48 V SELV/PELV (–25…+15 %). Typical consumption is below 15 W.

Which mounting options exist?

A flush-mounting enclosure, the surface-mounted enclosure B95061915 and the mounting frame B95061912 for a control cabinet door.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides