International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TECNA J-ROBOT-39067 single-phase welding transformer, 75 kVA

Single-phase TECNA J-ROBOT-39067 transformer rated at 75 kVA for resistance welding machines. Liquid cooling and epoxy resin encapsulated windings, made in Italy. Suited to robotic tongs and automatic resistance welding stations.

Brand
TECNA
Country of manufacture
Italy
Model code
J-ROBOT-39067
Type
single-phase transformer for resistance welding

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TECNA J-ROBOT-39067 is rated at 75 kVA, a mid-range output within the manufacturer's J-ROBOT line of transformers built for robots. The extra capacity is usually reserved for tongs with a longer reach, stacks of several sheets and galvanised steel, where a spot needs more current. The J-ROBOT prefix shows the unit is intended for robotic use, and the technology is single-phase alternating current.

In a robotic cell the transformer is matched to the tongs. Arm reach, the cross-section of the secondary busbars and the current needed at the weld point together decide whether 75 kVA is enough. The robot welds without pauses for an operator, so the coolant circuit has to keep running for as long as the cell is in operation.

Cooling is by liquid, as on every TECNA transformer, and the windings are encapsulated in epoxy resin. A unit like this should never run without a coolant supply, because the liquid alone carries heat away from the secondary circuit. The resin shields the windings from dust, spatter and moisture and holds them firmly in place.

TECNA builds its transformers to ISO 5826, ISO 10656 and ISO 22829, the standards covering resistance welding equipment. Alongside single-phase AC models such as this one, the manufacturer also offers three-phase DC transformers up to 1500 kVA, inverter DC units up to 664 kVA and special designs for particular duties.

The welding current is set by a thyristor phase-control unit, while the transformer lowers the mains voltage to the secondary level and raises the current. When a machine is upgraded, the controller and the secondary busbars are normally checked together with the transformer. To confirm the match, send the mains voltage and frequency, the secondary voltage, the welding type and the coolant parameters, and TECNA checks them against the model code.

Technical specifications

BrandTECNA
Country of manufactureItaly
Model codeJ-ROBOT-39067
Typesingle-phase transformer for resistance welding
Power75 kVA
Technologysingle-phase, alternating current
Coolingliquid
Winding insulationepoxy resin encapsulation
StandardsISO 5826, ISO 10656, ISO 22829
Applicationsresistance welding machines, heating, upsetting

Request a price and lead time

TECNA J-ROBOT-39067 single-phase welding transformer, 75 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the power rating of the TECNA J-ROBOT-39067?

The manufacturer gives 75 kVA for the J-ROBOT-39067, a single-phase unit on alternating current. TECNA confirms the primary and secondary voltages against the model code.

Does the transformer need separate cooling?

Yes, every TECNA transformer is liquid cooled, so the machine must be connected to a coolant circuit.

What does the J-ROBOT prefix mean?

The prefix places the model among units built for robotic welding. Compatibility with particular tongs and robots is agreed with TECNA against the J-ROBOT-39067 code.