TECNA 6090/6638 three-phase DC spot and projection welders, 100-630 kVA
The TECNA 6090/6638 series covers heavy three-phase direct current machines for spot and projection welding. According to the specification table, power runs from 100 to 480 kVA and maximum welding current from 48 to 150 kA, with a TE553 control unit fitted.
- Brand
- TECNA
- Country of manufacture
- Italy
- Items
- 6090/6638
- Machine type
- three-phase, direct current, linear action
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Item 6090/6638 brings together the largest three-phase direct current machines in the TECNA range, with linear electrode travel. The name covers 100 to 630 kVA, while the parameter table lists versions at 100, 160, 250, 400 and 480 kVA. Maximum welding current runs from 48 to 150 kA across those versions, short-circuit current from 60 to 190 kA and thermal current from 11 to 24 kA. Secondary voltage depends on the version and lies between 5.5 and 10.2 V. The machines are intended for spot and projection welding.
A three-phase rectified supply loads all three phases evenly and keeps the power factor high. It draws less from the plant's primary supply than a single-phase AC machine would, and installation costs are lower. Magnetic materials between the arms have a smaller influence on the welding current. A six-phase silicon rectifier supplies the current. Synchronous SCR contactors are insulated from the cooling water circuit and carry thermal protection. The TE553 control unit gives a direct read-out of the welding current.
Pneumatic cylinders have chrome-plated rods and low-friction seals that work without lubrication, so there is no oil mist. The double stroke is adjustable and switched with a key. Stems are cylindrical with an adjustable anti-rotation device, and the guides are prismatic precision roller guides. The pneumatic cycle is complex, with a gentle, low-force approach of the electrodes, and a pressure programme with a forging function is available to order. The electrodes can be lowered without pressure for setup and maintenance. An air filter with receiver and an air disconnect device are included.
Water cools the transformer, platens, electrode holders and electrodes, and the transformer windings are coated in epoxy resin. A flow switch works with both mains water and a recirculated cooling circuit, and it stops the machine if no water flows. A valve shuts off the water when the machine is off. The two-stage foot pedal clamps the workpiece only when it is correctly positioned, and a second pedal calls programme No. 2. Two-hand control with a timer and key selector, an emergency stop and an automatic circuit breaker are included.
Technical specifications
| Brand | TECNA |
|---|---|
| Country of manufacture | Italy |
| Items | 6090/6638 |
| Machine type | three-phase, direct current, linear action |
| Welding type | spot and projection |
| Power range (in name) | 100-630 kVA |
| Power (per table) | 100, 160, 250, 400, 480 kVA |
| Maximum welding current | 48, 72, 85, 120, 150 kA |
| Short-circuit current | 60, 90, 106, 150, 190 kA |
| Thermal current | 11, 13, 15, 18, 24 kA |
| Secondary voltage | 5.5, 5.9, 6.3, 6.8, 6.9, 7.1, 7.3, 7.6, 7.9, 8, 8.4, 8.8, 9.04, 9.5, 10.2 V |
| Control unit | TE553, direct read-out of welding current |
| Rectifier | six-phase silicon |
| Cooling | water, mains or recirculated, with flow switch |
| Protection | automatic circuit breaker |
Request a price and lead time
TECNA 6090/6638 three-phase DC spot and projection welders, 100-630 kVA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the maximum welding current in the TECNA 6090/6638 series?
The table gives 48 to 150 kA depending on the version, with power from 100 to 480 kVA.
Why is a three-phase DC machine easier on the plant's mains?
The load is spread evenly over three phases, the power factor is high, and the primary supply is loaded less than by a single-phase AC machine.
What water supply does the cooling need?
The flow switch works with both mains water and a recirculated cooling circuit.