TECNA 32980 single-phase welding transformer, 40 kVA
Built in Italy, the TECNA 32980 is a 40 kVA single-phase transformer aimed at spot and projection welding machines. Liquid cooling is required, the windings are protected by epoxy resin, and the rating matches mid-thickness sheet in series work. Heating and upsetting are also listed among its uses.
- Brand
- TECNA
- Country of manufacture
- Italy
- Model (code)
- 32980
- Type
- single-phase transformer for resistance welding
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The TECNA 32980 occupies the middle of the single-phase range at 40 kVA. Compared with the smaller codes it offers a larger current margin on the secondary circuit, and compared with the bigger ones it places a lighter load on the mains. It is a working class for serial spot welding of mid-thickness sheet on alternating current.
Transformers in the 40 kVA class go into press-type spot welding machines, rocker-arm machines of increased power and stationary stations on conveyor lines. Typical jobs for the 32980 are spot welds on steel sheet in series, the fixing of nuts and studs, projection welding of small parts, and heating and upsetting of blanks.
The 32980 is built like the rest of the TECNA range, with a body filled with epoxy resin and internal channels for liquid. The coolant carries heat away from the windings, which is why the machine is hooked up to a chiller or to the plant's cooling network. The resin section tolerates vibration and the dusty air of a workshop.
TECNA's standard programme is supplemented by special transformers for particular jobs, including heating and upsetting, and the 32980 conforms to ISO 5826, ISO 10656 and ISO 22829 like the whole line. The transformers are made in Italy, and the company has more than 40 years of experience with welding transformers.
To match the 32980 you need the mains voltage and frequency, the required secondary voltage, the type of welding and the cooling circuit parameters. The manufacturer publishes a 40 kVA rating for this model and TECNA confirms the rest from the code. For a replacement, send a photo of the nameplate so that the build can be checked. During operation, watch the flow and outlet temperature of the liquid, the condition of the primary terminal insulation and the cleanliness of the secondary contact faces. Oxidised or loose joints raise the circuit resistance, so the current at the electrodes falls and the transformer heats up more. Such spots are cleaned and retightened during planned stops.
Technical specifications
| Brand | TECNA |
|---|---|
| Country of manufacture | Italy |
| Model (code) | 32980 |
| Type | single-phase transformer for resistance welding |
| Power | 40 kVA |
| Technology | single-phase, alternating current |
| Cooling | liquid |
| Winding insulation | epoxy resin encapsulation |
| Standards | ISO 5826, ISO 10656, ISO 22829 |
| Applications | spot and projection welding machines, heating, upsetting |
Request a price and lead time
TECNA 32980 single-phase welding transformer, 40 kVA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the rating of the TECNA 32980 transformer?
The manufacturer gives 40 kVA for model 32980, and the technology is single-phase on alternating current. TECNA confirms the primary and secondary voltages from the model code.
Is separate cooling needed for the 32980?
Yes, every TECNA transformer is liquid cooled, so the machine must be connected to a coolant circuit.
Can the 32980 replace an old transformer?
It can if the 40 kVA rating, the secondary voltage and the mounting dimensions match. A photo of the old transformer's nameplate allows the check.
Similar equipment from other manufacturers