TECNA 32282 single-phase welding transformer, 63 kVA

The TECNA 32282 is a 63 kVA single-phase transformer for resistance welding machines. It is liquid cooled, has epoxy resin encapsulated windings and is made in Italy. It suits stationary spot machines with a rocker arm or pneumatic drive for sheet steel.

Brand
TECNA
Country of manufacture
Italy
Model (code)
32282
Type
single-phase transformer for resistance welding

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TECNA 32282 is rated at 63 kVA, the same power as another single-phase model from the manufacturer that carries a different code. Differences between such models usually lie in the winding voltages and in the construction for a particular machine, so selection is based on the code 32282 rather than on the kVA figure alone. At this rating it occupies the middle of the single-phase TECNA range and suits stationary spot machines with a rocker arm drive.

Transformers of around 63 kVA are most often fitted to stationary spot machines with a rocker arm or pneumatic drive for sheet steel. The rating decides which currents the machine can deliver at a given arm reach, and longer arms or a larger window call for more margin.

The TECNA 32282 is liquid cooled, its windings are encapsulated in epoxy resin, and the whole unit is manufactured in Italy. A potted transformer tolerates the conditions of a welding workshop better, and the liquid circuit keeps the winding temperature steady during frequent weld cycles. Connecting the cooling circuit forms part of the machine installation.

The unit conforms to ISO 5826, ISO 10656 and ISO 22829, and it is a single-phase alternating current design. Where a machine needs direct current, TECNA offers three-phase transformers up to 1500 kVA and inverter units up to 664 kVA, and it builds special versions for non-standard jobs.

Set-up of the 32282 follows the same logic as any single-phase contact unit. A control unit regulates the primary side through its thyristor contactor, while the secondary loop, built with only a few turns, carries a heavy current at low voltage to the electrodes. Weld time, current and pause settings come from that control unit, and the transformer is the element that turns mains power into welding current. Only the 63 kVA figure is published for this model, and TECNA supplies the rest from the model code. A replacement check therefore needs the supply voltage, the secondary voltage, the method of connecting the unit to the busbars and the cooling hook-up. The nameplate code and a photo of the mounting position are usually enough to proceed.

Technical specifications

BrandTECNA
Country of manufactureItaly
Model (code)32282
Typesingle-phase transformer for resistance welding
Power63 kVA
Technologysingle-phase, alternating current
Coolingliquid
Winding insulationepoxy resin encapsulation
StandardsISO 5826, ISO 10656, ISO 22829
Applicationsresistance welding machines, heating, upsetting

Request a price and lead time

TECNA 32282 single-phase welding transformer, 63 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the rating of the TECNA 32282 transformer?

The manufacturer gives 63 kVA for model 32282, with single-phase alternating current technology. TECNA confirms the primary and secondary voltages from the model code.

Is separate cooling required?

Yes, all TECNA transformers use liquid cooling, so the machine must be connected to a coolant circuit.

How does the 32282 differ from another model of the same rating?

The manufacturer lists 63 kVA for both, and the difference lies in the build and the winding voltages. That is why the unit is ordered by the code 32282.