International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Synchronous condensers, including 50 Mvar / 35 kV direct-connected

Synchronous condensers, including distributed ones, for voltage support and reactive power control in power systems. The versions include a high-voltage direct-connected 50 Mvar / 35 kV condenser, connected to the grid without a step-up transformer. Manufactured in Harbin (China).

Model
50 Mvar / 35 kV, high-voltage, direct-connected
Connection
to a 35 kV grid without a step-up transformer
Cooling
air / air-water (according to the page)
Response
millisecond

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A synchronous condenser works as a synchronous machine without a mechanical load on the shaft. By changing the excitation current, it supplies reactive power to the grid or absorbs it, and the rotating mass of the rotor adds inertia to the power system. Condensers are installed in grids with a high share of wind and solar generation, where they support voltage, control reactive power and improve power system stability. The second area of use is converter substations of DC lines, where the condenser supports the voltage on the converter busbars.

The 50 Mvar high-voltage machine is connected directly to a 35 kV grid. Without an intermediate transformer, according to the manufacturer, operating efficiency grows and life-cycle costs fall. The substation scheme becomes simpler, because it has no separate transformer with its own protection and maintenance. Cooling is air-water, although the manufacturer's page also mentions a fully air-cooled version, so the cooling type is clarified when ordering.

The condenser has millisecond response, high performance in transient and steady-state modes, and overload capability. Fast response is needed during voltage dips, when the machine must immediately supply reactive power to the grid. The cooling system and the simple design make installation, operation and maintenance easier. The manufacturer produces distributed condensers as a separate line alongside grid machines.

The full range of outputs and voltages is not given in the available materials. Parameters for a specific substation, wind farm or solar plant are determined on request, based on the required reactive power, the voltage class of the grid and the connection scheme. For a request, data on the connection point, the short-circuit power of the grid and the required reactive power range are needed.

Technical specifications

Model50 Mvar / 35 kV, high-voltage, direct-connected
Connectionto a 35 kV grid without a step-up transformer
Coolingair / air-water (according to the page)
Responsemillisecond
Rangesynchronous condensers and distributed condensers

Request a price and lead time

Synchronous condensers, including 50 Mvar / 35 kV direct-connected. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Is a step-up transformer needed for the 50 Mvar condenser?

No, the high-voltage 50 Mvar condenser is connected directly to a 35 kV grid. According to the manufacturer, this reduces life-cycle costs.

What facilities are synchronous condensers intended for?

For power systems with a high share of wind and solar generation, where voltage support, inertia and stability are needed, and also for converter substations of DC lines.

What cooling does the condenser have?

The manufacturer's materials state air-water cooling, and the page also mentions fully air cooling. The version is clarified when ordering.