SVC / DVR / APF – reactive power compensation and power quality devices

SVC, DVR and APF are power equipment for improving power quality. The range covers static thyristor compensators SVC, dynamic voltage restorers DVR and active harmonic filters APF. The devices regulate voltage and reactive power, compensate voltage sags and suppress higher harmonics in utility and industrial networks.

SVC
380–440 V, 6.6 kV, 22.9 kV; 500 kVA – 100 MVA
DVR
100/200/300/500 kVA and 1000/2000 kVA; 200/380/440 V, 6.6 kV, 22.9 kV
APF
3P3W and 3P4W, 100–400 kVA
Diagnostics
online monitoring, UHF partial discharge diagnostics, breaker contact wear prediction

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The equipment solves three groups of tasks, namely voltage and reactive power regulation, compensation of voltage sags and suppression of higher harmonics in utility and industrial networks. For this purpose static thyristor compensators (SVC), dynamic voltage restorers (DVR) and active harmonic filters (APF) are used.

SVC (Static Var Compensator). According to the manufacturer's overview brochure, the compensators are made for voltages of 380–440 V, 6.6 kV and 22.9 kV with ratings from 500 kVA to 100 MVA. They provide fast dynamic compensation of reactive power, stabilise voltage and reduce flicker under sharply varying loads such as arc furnaces, rolling mills and large drives. In addition, SVCs improve the stability of power systems.

DVR (Dynamic Voltage Restorer). Voltage restorers rated 100, 200, 300 and 500 kVA, as well as 1000 and 2000 kVA, are made for voltages of 200, 380 and 440 V, 6.6 kV and 22.9 kV. The DVR compensates short-term sags and overvoltages of the network and protects sensitive production from stoppages, including semiconductor and chemical plants and data centres.

APF (Active Power Filter). Active harmonic filters are made for three-phase three-wire (3P3W) and four-wire (3P4W) networks rated 100–400 kVA. They suppress higher harmonics from frequency converters, rectifiers and UPS units and compensate reactive power.

Beyond power equipment, the manufacturer offers diagnostic systems, namely online monitoring for preventive maintenance, partial discharge diagnostics by the UHF method and contact life prediction for SF6 circuit breakers. Typical sites are utility substations of 6–35 kV, metallurgy and heavy industry, data centres, semiconductor production and renewable energy facilities. Circuits, response times and ratings are not given in the available materials.

Technical specifications

SVC380–440 V, 6.6 kV, 22.9 kV; 500 kVA – 100 MVA
DVR100/200/300/500 kVA and 1000/2000 kVA; 200/380/440 V, 6.6 kV, 22.9 kV
APF3P3W and 3P4W, 100–400 kVA
Diagnosticsonline monitoring, UHF partial discharge diagnostics, breaker contact wear prediction

Request a price and lead time

SVC / DVR / APF – reactive power compensation and power quality devices. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What ratings and voltages do the SVC compensators have?

According to the manufacturer's overview brochure, SVC compensators are made for voltages of 380–440 V, 6.6 kV and 22.9 kV with ratings from 500 kVA to 100 MVA.

What ratings and voltages are available for the DVR voltage restorers?

Ratings of 100, 200, 300 and 500 kVA, as well as 1000 and 2000 kVA. Voltages of 200, 380 and 440 V, 6.6 kV and 22.9 kV.

Which networks are the APF active filters intended for?

For three-phase three-wire (3P3W) and four-wire (3P4W) networks rated 100–400 kVA. The filters suppress higher harmonics from frequency converters, rectifiers and UPS units.