International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Zero-cross solid state relays with back-to-back SCR output, 24 to 660 V AC, up to 75A

Single-phase solid state relays for switching resistive heaters on furnaces, extruders, ovens and dryers. Zero-cross firing on a short time-proportioning cycle holds process temperature closer than a slow-cycling contactor and is kinder to the heating elements.

Type
single-phase solid state relay
Load voltage
24 to 660 V AC; separate DC model
Maximum current
75A
Output device
inverse parallel SCRs

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Heater life is the main argument for this relay range. Firing at the voltage zero crossing and cycling every tenth of a second (1⁄10 s), the relay feeds the element in small, even bursts rather than long on-off periods, so temperature control tightens and the element avoids repeated thermal shock. The manufacturer's own testing points to longer heater life than with slow-cycle relays, at a lower cost than a full SCR power controller.

On AC models the output stage uses two SCRs in inverse parallel instead of a triac, which copes better with high currents and the electrically noisy conditions found on heavy industrial sites. Low and high voltage versions together span 24 to 660 V AC, the top current rating in the range is 75A, and a separate switched DC model is offered for DC heating. All versions are single phase with zero-cross output firing.

Relays mount on the back panel of the enclosure onto a heat sink. Each comes with a thermal foil pad to carry heat from the relay base into the sink, and Belleville washers to keep the clamping pressure correct. Matched semiconductor fuses and heat sinks can be ordered to make up a complete switching assembly, and add-on cards are available to flag a shorted output.

Listed approvals are UL® and CSA, together with an SCCR rating for panels marked with fault current. Ambient operating range is given as 25 to 85 °C.

Technical specifications

Typesingle-phase solid state relay
Load voltage24 to 660 V AC; separate DC model
Maximum current75A
Output deviceinverse parallel SCRs
Firingzero cross
Phases1
Mountingback panel, on heat sink
Ambient operating range25 to 85 °C
ApprovalsUL®, CSA, SCCR
Supplied withthermal foil, Belleville washers

Request a price and lead time

Zero-cross solid state relays with back-to-back SCR output, 24 to 660 V AC, up to 75A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Why choose an SSR over a mechanical contactor for heaters?

Zero-cross switching on a 1⁄10 second cycle gives tighter temperature control. Heaters driven this way last longer than with slow-cycle relays.

What voltage and current ratings are available?

Versions cover 24 to 660 V AC, with up to 75A in the range. A switched DC model is offered for DC heating loads.

What is needed to install the relay?

A heat sink, plus the thermal foil and Belleville washers supplied with the relay. Matched semiconductor fuses are recommended for protection.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides