
WATCONNECT Large and Extra-Large thermal system control panels, 720A to 4,320A FLA
Large and extra-large control panels for high-power electric heating systems. The control compartment can be opened safely while the process runs, the footprint is up to 50% smaller than comparable panels, and an optional Data Insights package adds thermal system analytics.
- Large, single bay
- Up to 720A FLA, 800 mm wide
- XL, two bay
- Up to 1440A FLA, 1600 mm wide
- XL, 3–7 bays
- Up to 4,320A FLA, 2400–5800 mm wide
- Voltage (three phase)
- 230/240V, 380/400/415V, 440/460/480V, 575/600V, 690V (50 or 60 Hz)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Floor space in a control room is rarely spare, and stopping a furnace to trace a fault is expensive. These panels address both points: they take up to 50% less room than competing designs, and the control compartment, along with the fan compartment, stays safely accessible while the heaters keep running.
Three build sizes are offered. A Large single-bay panel handles up to 720A FLA in an 800 mm width. The XL two-bay version with two disconnects reaches 1440A FLA at 1600 mm, while XL panels of 3 to 7 bays on a single disconnect go up to 4,320A FLA across 2400 to 5800 mm. Each bay measures 2000H x 800W x 600D mm, standing on a 200 mm plinth indoors or a 300 mm leg kit outdoors. Three-phase supplies of 230/240V, 380/400/415V, 440/460/480V, 575/600V or 690V at 50 or 60 Hz are covered.
Enclosures come in powder-coated carbon steel, RAL 7035, or brushed SS316, rated Type 1 (IP42), Type 4 (IP65) or Type 4X (IP65). Ambient range is 0 to 40°C, extended to -18 to 40°C with a space heater. Approvals include UL / cUL 508A for safe areas, Class I, Div II, Groups B/C/D and Class I, Zone 2, IIA, IIB, IIC, with CE self-declaration to EN 61439 for Europe.
Inside there is a solid copper power interconnect that moves less with temperature, health monitoring of the panel environment and field connections, and resettable components in place of consumable spares. Heater upset protection is handled by a PM6 limit controller.
The optional Data Insights package adds a cellular gateway that reads the controllers over Modbus TCP/RTU and sends data one way to a secure cloud via MQTT. Specialists review controller health, failed elements and process drift, and the customer receives a quarterly report.
Technical specifications
| Large, single bay | Up to 720A FLA, 800 mm wide |
|---|---|
| XL, two bay | Up to 1440A FLA, 1600 mm wide |
| XL, 3–7 bays | Up to 4,320A FLA, 2400–5800 mm wide |
| Voltage (three phase) | 230/240V, 380/400/415V, 440/460/480V, 575/600V, 690V (50 or 60 Hz) |
| Bay dimensions | 2000H x 800W x 600D mm + 200 mm plinth or 300 mm leg kit |
| Enclosure | Carbon steel RAL 7035 or SS316 |
| Environmental rating | Type 1 (IP42), Type 4 (IP65), Type 4X (IP65) |
| Ambient temperature | 0 to 40°C without heater; -18 to 40°C with heater |
| Approvals | UL / cUL 508A; Class I, Div II, Groups B/C/D; Class I, Zone 2, IIA, IIB, IIC |
| Europe | CE self-declared to EN 61439 |
| Option | Data Insights package, Modbus TCP/RTU, MQTT |
Request a price and lead time
WATCONNECT Large and Extra-Large thermal system control panels, 720A to 4,320A FLA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the panel be serviced without stopping the process?
Yes, the control and fan compartments remain accessible during operation, so faults can be traced without a shutdown.
Are hazardous-area versions available?
Yes, approvals cover Class I, Div II, Groups B/C/D and Class I, Zone 2, IIA, IIB, IIC.
What is the highest current rating in the range?
The XL version with 3 to 7 bays on a single disconnect is rated up to 4,320A FLA.
Similar equipment from other manufacturers






