Tube and wire thermocouples for medium-duty processes, up to 480 °C
General-purpose thermocouples supplied either as flexible insulated wire or with a rigid metal sheath. They suit medium-duty process temperatures up to 480 °C, with food production and metals processing among the typical users.
- Type
- insulated-wire and metal-sheathed tube thermocouples
- Temperature
- up to 480 °C (900 °F)
- Outside diameter
- 3.2, 4.8 or 6 mm (0.125, 0.1875 or 0.25 in)
- Wire insulation
- woven fibreglass or high-temperature engineered resins
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A metal sheath fitted over the thermocouple is what turns the wire version into a tube probe. The sheath stiffens the assembly so it can be placed accurately at the measuring point, and it shields the sensing junction. Sheath outside diameters are 3.2, 4.8 or 6 mm, equivalent to 0.125, 0.1875 or 0.25 in.
Where no sheath is needed, the flexible thermocouple wire is insulated with woven fibreglass or with high-temperature engineered resins. Cable that runs past moving parts or sharp edges can be finished with a stainless steel wire braid or flexible armour against abrasion. Standard catalogue thermocouple types are identified by ASTM E230 colour coding, which helps during wiring and maintenance.
Maximum temperature for the range is 480 °C (900 °F), placing it in medium-duty territory: process equipment in food plants and metals processing, plus industrial and commercial machinery where a simple, serviceable sensor is preferred.
Fixing options include springs, ring terminals, specialised bolts, pipe-style clamps and shims, so the probe can be secured to a surface, held in a bore or clamped to a pipe. When making an enquiry, describe the mounting method, the required length and the lead termination, and the configuration will be agreed against your drawing.
Technical specifications
| Type | insulated-wire and metal-sheathed tube thermocouples |
|---|---|
| Temperature | up to 480 °C (900 °F) |
| Outside diameter | 3.2, 4.8 or 6 mm (0.125, 0.1875 or 0.25 in) |
| Wire insulation | woven fibreglass or high-temperature engineered resins |
| Extra protection | stainless steel wire braid, flexible armour |
| Colour coding | to ASTM E230 |
| Mounting | springs, ring terminals, special bolts, pipe-style clamps, shims |
| Duty | medium-duty processes |
Request a price and lead time
Tube and wire thermocouples for medium-duty processes, up to 480 °C. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the maximum operating temperature?
Up to 480 °C (900 °F), which covers medium-duty process applications.
Which sheath diameters are offered?
3.2, 4.8 or 6 mm outside diameter, that is 0.125, 0.1875 or 0.25 in.
How can the leads be protected from abrasion?
Specify a stainless steel wire braid or flexible armour over the fibreglass or resin insulation.