International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TR radio frequency thermocouple probe for plasma equipment, up to 500 °C, 3000 V DC

Where radio frequency energy or conducted interference would throw an ordinary sensor's reading badly off, the TR probe keeps the measurement honest. Its main home is plasma generation equipment, including platens running with a DC bias.

Model
TR
Purpose
temperature measurement in plasma generation equipment
Temperature
up to 500 °C (932 °F); 260 °C or 500 °C versions
Outside diameter
5 mm (0.19 in)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Several design choices work together here. The tip is made from high thermal conductivity materials and is spring-loaded against the surface, giving a quick response and repeatable readings. High dielectric insulation separates the sensor from capacitive coupling and is rated at 3000 V DC, which is what allows the probe to sit in a DC-biased platen. The lead wires are twisted to raise common-mode rejection and reduce errors induced by electromagnetic interference.

The reason for all this is simple. In a plasma chamber, RF energy couples into the sensor circuit, and a conventional thermocouple can then report a temperature that is seriously wrong. The TR is built so that this effect does not reach the measurement.

Calibration is type K. The probe has a 5 mm (0.19 in) outside diameter and an upper limit of 500 °C (932 °F); constructions rated for 260 °C and for 500 °C are offered. Immersion depth can be chosen between 22.23 mm and 38.1 mm (0.875 in and 1.5 in).

For mounting there is a stainless steel threaded fitting, either 5/16-18 or M8. The platen needs a machined pocket to the manufacturer's detail drawing. With an enquiry, please state the temperature rating, immersion depth, thread type and lead length.

Technical specifications

ModelTR
Purposetemperature measurement in plasma generation equipment
Temperatureup to 500 °C (932 °F); 260 °C or 500 °C versions
Outside diameter5 mm (0.19 in)
Dielectric rating3000 V DC
Calibrationtype K
Immersion depth22.23 mm to 38.1 mm (0.875 in to 1.5 in)
Threaded fitting5/16-18 or M8, stainless steel
Tipthermally conductive, spring-loaded
Leadstwisted, high common-mode rejection

Request a price and lead time

TR radio frequency thermocouple probe for plasma equipment, up to 500 °C, 3000 V DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the TR be fitted in a platen with DC bias?

Yes, the 3000 V DC dielectric rating is intended for exactly that installation.

Which temperature versions are available?

Two constructions, rated 260 °C and 500 °C, both with type K calibration.

How is the probe secured?

With a stainless steel threaded fitting, 5/16-18 or M8, at an immersion depth of 22.23 mm to 38.1 mm.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides