TIM Temperature Input Module for NCS, 4 Configurable Channels, DIN Housing

The TIM is a universal temperature input module for the NCS Net Concentrator System. Its four configurable channels accept RTD, thermocouple, mV, ohms and potentiometer inputs, in a DIN housing for a 35mm Top Hat rail.

Type
universal temperature input module for NCS
Typical model
TIM/IO/AI4/IP [DIN]
Channels
4, configurable
Input types
RTD, T/C, mV, ohms, potentiometer

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TIM is a universal temperature input module for the NCS Net Concentrator System. Other NCS modules are the AIM, AOM, CPM, DIM, EMM and ROM. The TIM serves as an input module on the NCS network: temperature sensor signals are gathered in the module and passed on over the network of the system.

The module has four configurable temperature input channels. The input type of each channel is set separately as RTD, thermocouple (T/C), millivolt, ohms or potentiometer. In the typical model TIM/IO/AI4/IP the IO input means an input/output module and the AI4 output means four analogue inputs. The module has no math or logic capability; in an NCS those functions are handled by another module.

The DIN-style housing mounts on a 35mm Top Hat rail. Non-incendive (Div. 2, Zone 2) hazardous area certification is listed, and the module is RoHS compliant.

Configuration is done as part of the NCS system with the NCS software, which is supplied separately from the module.

Technical specifications

Typeuniversal temperature input module for NCS
Typical modelTIM/IO/AI4/IP [DIN]
Channels4, configurable
Input typesRTD, T/C, mV, ohms, potentiometer
Network typeNCS system
Math or logic capabilityno
HousingDIN-style, 35mm Top Hat rail
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2
RoHScompliant

Part numbers

Show all part numbers (1)

TIM/IO/AI4/IP [DIN]

How it compares with similar models

ParameterTIM Temperature Input Module for NCS, 4 Configurable Channels, DIN HousingEMM Ethernet/MODBUS Interface Module for NCS, DIN Housing, Up to 16 I/O ModulesAOM Analog Output Module for NCS, 4 channels 0-20 mA or 0-10 VAIM Analog Input Module for NCS, 4 channels 0-20 mA or -10 to 10 V
Typeuniversal temperature input module for NCSEthernet/MODBUS interface module for NCSUniversal analogue output module for NCSUniversal analogue input module for NCS
Network typeNCS systemNCS system, peer to host, peer to peerNCS systemNCS system
HousingDIN-style, 35mm Top Hat railDIN-style, 35mm Top Hat railDIN-style, 35 mm Top Hat railDIN-style, 35 mm Top Hat rail
RoHScompliantcompliantYesYes

Request a price and lead time

TIM Temperature Input Module for NCS, 4 Configurable Channels, DIN Housing. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many channels does the TIM have and which inputs?

Four configurable channels for RTD, thermocouple, mV, ohms or potentiometer.

Does the TIM have math or logic functions?

No, the module has no math or logic capability.

How is the TIM mounted?

In a DIN-style housing on a 35mm Top Hat rail.