International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

AOM Analog Output Module for NCS, 4 channels 0-20 mA or 0-10 V

The AOM is a universal analog output module for the NET Concentrator System (NCS). It offers four configurable channels of 0-20 mA or 0-10 V. The DIN-style housing mounts on 35 mm Top Hat rail, and the module is listed Non-Incendive/Div. 2, Zone 2.

Model
AOM/IO/AI4/IP [DIN]
Type
Universal analogue output module for NCS
Outputs
4 configurable analogue channels (0-20 mA, 0-10 V)
Output type
Analogue

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

AOM/IO/AI4/IP [DIN] is the universal analog output module of the NET Concentrator System (NCS). The same system includes the AIM, CPM, DIM, EMM, ROM and TIM modules. The AOM sends signals out to field circuits, taking them from the host system through the interface module of the NCS network.

The module carries four configurable analogue output channels, each available as 0-20 mA or 0-10 V. The output type is analogue and the network type is the NCS system. The module has no maths or logic capability.

The DIN-style housing mounts on 35 mm Top Hat rail. For hazardous areas the module is listed Non-Incendive/Div. 2, Zone 2. It is RoHS compliant.

DXF and DWG drawings and a 3D CAD model are available for the module.

The NCS gathers field signals and carries them over a single network. The AOM handles analogue outputs, while the AIM, DIM and TIM modules take inputs, the ROM provides relay outputs and the CPM adds power for further modules.

In the order code AOM/IO/AI4/IP [DIN] the Input field is IO, the Output field is AI4 and the Power field is IP. The AI4 designation corresponds to four configurable analogue outputs, and the module performs no maths or logic operations.

Technical specifications

ModelAOM/IO/AI4/IP [DIN]
TypeUniversal analogue output module for NCS
Outputs4 configurable analogue channels (0-20 mA, 0-10 V)
Output typeAnalogue
Network typeNCS system
Math or logicNo
HousingDIN-style, 35 mm Top Hat rail
Hazardous area certificationNon-Incendive/Div. 2, Zone 2
RoHSYes

Part numbers

Show all part numbers (1)

AOM/IO/AI4/IP [DIN]

Request a price and lead time

AOM Analog Output Module for NCS, 4 channels 0-20 mA or 0-10 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many channels does the AOM have, and which ranges?

Four configurable analogue outputs, each with 0-20 mA or 0-10 V ranges.

Which rail does the module mount on?

The DIN-style housing mounts on 35 mm Top Hat rail.

Does the AOM carry a hazardous area certification?

Yes, it is listed Non-Incendive/Div. 2, Zone 2.