International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

AIM Analog Input Module for NCS, 4 channels 0-20 mA or -10 to 10 V

The AIM is a universal analogue input module of the NET Concentrator System (NCS). It has four configurable channels, set for 0-20 mA current or -10 to 10 V voltage. The DIN-style housing mounts on 35 mm Top Hat rail, and the module is listed Non-Incendive/Div. 2, Zone 2.

Model
AIM/IO/AI4/IP [DIN]
Type
Universal analogue input module for NCS
Inputs
4 configurable analogue channels (0-20 mA, -10 to 10 V)
Input type
Configurable: current or voltage

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

AIM/IO/AI4/IP [DIN] is the universal analogue input module of the NET Concentrator System (NCS), which also includes the AOM, CPM, DIM, EMM, ROM and TIM modules. The AIM takes analogue signals from the field and passes them onto the NCS network for the host system.

The module has four configurable analogue input channels. The input type is chosen as current or voltage, with ranges of 0-20 mA or -10 to 10 V. The network type is the NCS system. The module has no maths or logic capability.

The DIN-style housing mounts on 35 mm Top Hat rail. For hazardous areas the module is listed Non-Incendive/Div. 2, Zone 2. It is RoHS compliant.

DXF and DWG drawings and a 3D CAD model are offered for the module. Output signals in the same system are produced by the AOM and ROM modules.

In the order code AIM/IO/AI4/IP [DIN] the fields give input IO, output AI4 and power IP.

The AI4 designation in the code corresponds to four configurable analogue inputs, and the input type of each channel is chosen between current and voltage. Maths and logic functions are absent.

Technical specifications

ModelAIM/IO/AI4/IP [DIN]
TypeUniversal analogue input module for NCS
Inputs4 configurable analogue channels (0-20 mA, -10 to 10 V)
Input typeConfigurable: current or voltage
Network typeNCS system
Math or logicNo
HousingDIN-style, 35 mm Top Hat rail
Hazardous area certificationNon-Incendive/Div. 2, Zone 2
RoHSYes

Part numbers

Show all part numbers (1)

AIM/IO/AI4/IP [DIN]

Request a price and lead time

AIM Analog Input Module for NCS, 4 channels 0-20 mA or -10 to 10 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many channels does the AIM have, and which ranges?

Four configurable analogue inputs, set for 0-20 mA or -10 to 10 V.

Which input types can the AIM take?

The input type is configurable: 0-20 mA current or -10 to 10 V voltage.

What hazardous area certification is listed?

Non-Incendive/Div. 2, Zone 2.