International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Sensor connection heads and terminal blocks for thermocouples and RTDs

Weatherproof housings that sit on top of a temperature sensor and protect the joint between its leads and the extension cable. Inside each one is a terminal block that the fitter can reach without pulling the probe out of the process.

Function
joining sensor leads to extension wiring
General-purpose heads
cast iron or aluminium
General-purpose head temperature
up to 441°C
Cable entry
3/4 inch NPT

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Every thermocouple, RTD or solid-state probe needs somewhere to land its wires. The connection head does that job: the element leads and the extension or compensating cable meet on a terminal block, and a screw-on cover keeps out dust, moisture and knocks. When an insert has to be changed or a loop checked, the cover comes off and the terminals are right there.

For hazardous areas there are explosion-proof heads. Their UL listing covers Class 1 (Groups C and D), Class 2 (E, F, G) and Class 3; the CSA approval covers Groups C and D in Class I, Groups E and F in Class II, and Class III. Refineries, chemical works, power stations and tank farm pipework are the usual homes for these.

General-purpose heads are cast in iron or aluminium and cope with up to 441°C at the head; the cable entry is threaded 3/4 inch NPT. Aluminium can be supplied with an epoxy finish. Polypropylene heads, UV-stabilised and good for 105°C, suit outdoor or corrosive locations, and a white version is listed. Sensor openings differ between models, so the head is chosen to match the sheath or thermowell in use.

Terminal blocks are sold to go with the heads and withstand up to 540°C. Single, dual and triplex blocks fit the standard heads, while the polypropylene heads take single or dual blocks. Pick the block by the number of sensing elements in the probe.

Technical specifications

Functionjoining sensor leads to extension wiring
General-purpose headscast iron or aluminium
General-purpose head temperatureup to 441°C
Cable entry3/4 inch NPT
Polypropylene headsUV-stabilised, up to 105°C
UL listing, explosion-proof headsClass 1 (Groups C, D), Class 2 (Groups E, F, G), Class 3
CSA approval, explosion-proof headsGroups C, D in Class I; Groups E, F in Class II; Class III
Terminal blockssingle, dual, triplex
Terminal block temperatureup to 540°C
Sensor typesthermocouples, RTDs, solid-state

Request a price and lead time

Sensor connection heads and terminal blocks for thermocouples and RTDs. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which head suits an outdoor installation?

A UV-stabilised polypropylene head works outdoors as long as the head stays below 105°C. Above that, use a cast iron or aluminium head, which handles up to 441°C.

Are there heads for hazardous areas?

Yes. The explosion-proof version is UL listed for Class 1 (Groups C and D), Class 2 (E, F, G) and Class 3, and CSA approved for Groups C and D in Class I, Groups E and F in Class II, and Class III.

How many elements can one head terminate?

Standard heads take single, dual or triplex terminal blocks. Polypropylene heads are offered with single or dual blocks.

Similar equipment from other manufacturers