International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

PM LEGACY™ Panel-Mount PID or Limit Controller, 1/16 DIN and 1/32 DIN

A straightforward single-loop panel controller for basic heating and process duties, without the layers of features found on larger units. It is ordered either as a PID process controller or as a dedicated over- and under-temperature limit.

Function
PID process controller or temperature limit
Control loops
1
Inputs
1 universal
Outputs
up to 2

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Two DIN sizes are offered, 1/16 and 1/32, in the PM6 and PM3 builds, including simplified EXPRESS versions in both PID and limit form. Each unit has one universal input and up to two outputs, the heaviest rated at 15 A NO-ARC.

Tuning is handled by TRU-TUNE®+ adaptive control, and alarms and setpoint profiling are included. Bluetooth, Modbus® RTU and Standard Bus cover communications, and both PID and limit versions come with their own quick start and full user guides. The menu structure is short, so a basic loop can be commissioned without working through pages of rarely used parameters.

Listed approvals are UL®, CSA, CE, RoHS, W.E.E.E., FM and SEMI F47-0200, with a Class 1, Div. 2 rating on selected models. Units are built under ISO 9001-registered processes. For panel design, STEP, IGES and Parasolid models and AutoCAD drawings are available for each variant.

Technical specifications

FunctionPID process controller or temperature limit
Control loops1
Inputs1 universal
Outputsup to 2
Maximum output15 A NO-ARC
Adaptive tuningTRU-TUNE®+
Profilingyes
Alarmsyes
CommunicationsBluetooth, Modbus® RTU, Standard Bus
Mountingpanel, 1/16 DIN and 1/32 DIN
ApprovalsUL®, CSA, CE, RoHS, W.E.E.E., FM, SEMI F47-0200, Class 1 Div. 2 (selected models)

Request a price and lead time

PM LEGACY™ Panel-Mount PID or Limit Controller, 1/16 DIN and 1/32 DIN. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the PM LEGACY™ act as a safety temperature limit?

Yes. It is ordered as a dedicated over- and under-temperature limit controller instead of the PID version.

Which communications are available?

Bluetooth, Modbus® RTU and Standard Bus.

Is there a hazardous-location rating?

Selected models carry a Class 1, Div. 2 rating alongside FM, UL® and CSA approvals; the exact model code should be confirmed at enquiry.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides