NCS NET Concentrator System, modular process control and distributed I/O
The NET Concentrator System (NCS) is a modular distributed I/O family. One interface module plus I/O modules handle current, voltage, discrete, relay, RTD, thermocouple, resistance and potentiometer signals. The operating range is -40 to +85 °C.
- Model
- NCS
- Type
- Modular process control and distributed I/O system
- Interface modules
- MIM (MODBUS), EIM (Ethernet)
- I/O modules
- TIM, AIM, AOM, DIM, ROM, EMM
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The NET Concentrator System (NCS) is a modular family that links dispersed field-mounted monitoring and control equipment with the control room. It carries from a few to hundreds of process signals between the field or plant floor and the control room on a single communications network. A system is one interface module combined with one or more I/O modules.
Two interface modules are described. The MIM connects the system to a MODBUS RTU network and has two independent RS-485 ports. The EIM gives an Ethernet connection with a web server, data logger, security settings and MODBUS/TCP support. The I/O modules are the TIM for temperature inputs, AIM for analogue inputs, AOM for analogue outputs, DIM for discrete inputs, ROM for relay outputs and EMM, which carries the multipoint analogue alarm option. The interface module powers two I/O modules, and the CPM power module adds supply for the rest.
The system handles current, voltage, discrete, relay, RTD, thermocouple, resistance and potentiometer signals. The interface module scans the modules, collects the process data and keeps a database for host access. Modules join through DB-25 connectors on their sides and can be hot-swapped.
Modules snap onto 32 mm G-type rail (EN50035) or 35 mm Top Hat rail (EN50022). The operating range is -40 to +85 °C (-40 to +185 °F), the supply is 20-30 Vdc, and isolation is up to 1000 Vrms. MODBUS wiring needs shielded twisted pair. The system is RoHS compliant, CE marked and meets EN61326.
Configuration uses the NCSConfig PC software and the Network Addressing Configuration (NAC) client. The multipoint alarm option has its own MAA PC Configuration Software.
Technical specifications
| Model | NCS |
|---|---|
| Type | Modular process control and distributed I/O system |
| Interface modules | MIM (MODBUS), EIM (Ethernet) |
| I/O modules | TIM, AIM, AOM, DIM, ROM, EMM |
| Power module | CPM |
| Signal types | Current, voltage, discrete, relay, RTD, thermocouple, resistance, potentiometer |
| Protocol | MODBUS RTU (MIM), MODBUS/TCP (EIM) |
| Module connection | DB-25 connectors |
| Mounting | 32 mm G-type rail (EN50035) or 35 mm Top Hat rail (EN50022) |
| Supply | 20-30 Vdc |
| Operating temperature | -40 to +85 °C |
| Isolation | up to 1000 Vrms |
| Standards | EN61326, RoHS, CE |
Part numbers
Show all part numbers (10)
NCS, MIM, EIM, TIM, AIM, AOM, CPM, DIM, EMM, ROM
Request a price and lead time
NCS NET Concentrator System, modular process control and distributed I/O. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which modules make up an NCS?
One interface module (MIM for MODBUS RTU or EIM for Ethernet) and one or more I/O modules: TIM, AIM, AOM, DIM, ROM and EMM.
Which signals does the system handle?
Current, voltage, discrete, relay, RTD, thermocouple, resistance and potentiometer signals.
How is the NCS mounted, and what is the temperature range?
On 32 mm G-type rail (EN50035) or 35 mm Top Hat rail (EN50022), from -40 to +85 °C.