INSTATRANS / XD Intrinsically Safe O2 Transmitter, 4-20 mA, 0-10 ppm up to 0-25 %

A two-wire digital oxygen transmitter that reads anything from trace ppm levels to percent concentrations using a micro-fuel cell. It takes its power from the 4-20 mA loop and is marked II 1G Ex ia IIC T4 Ga for Zone 0 hazardous areas.

Measuring principle
micro-fuel cell
Range
single, 0-10 ppm up to 0-25 %
Accuracy
±1 % of span; ±1 ppm below 0-100 ppm
Response time T90
15 s; 40 s below 0-100 ppm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Inside the 316 stainless steel wetted cell compartment sits an electrochemical micro-fuel cell. The class B-2C cell covers trace oxygen and general duty, while A-2C, B-1, B-1C, A-5 and A-5C cells are fitted for special configurations. O-ring seals can be specified in Viton, Buna-N, Kalrez, EPDM, neoprene and several other elastomers.

The operator sets one measuring range anywhere from 0-10 ppm up to 0-25 %. Accuracy is ±1 % of the selected span, tightening to ±1 ppm on spans below 0-100 ppm, and T90 is 15 s, or 40 s on those low ppm spans. Readings show on the 4.5 digit LCD, and the same pair of wires carries both the 4-20 mA signal and the 9-24 V DC supply.

Typical duties include inert gas blanketing, air separation and liquefaction, chemical reaction monitoring, semiconductor fabs, petrochemical process control, quality assurance and certification of gas mixtures, in other words any stream where oxygen has to be caught at ppm level, including in potentially explosive atmospheres.

The housing is NEMA-4 (IP66), works between 0 °C and 50 °C and weighs approximately 6 pounds. A sample flow of 1-2 SCFH (0.5-1 SLPM) is recommended, with 1/8 inch, 1/4 inch or 6 mm tube fittings, or a 1/8 inch FNPT thread. The flying lead is 610 mm of two-core screened 22 AWG cable.

For Europe the transmitter is marked II 1G Ex ia IIC T4 Ga at 0 °C to 50 °C ambient; in North America it holds FM/FMc approval for Class I Division 1 and Division 2, gas groups A to D, T4. Entity parameters are Ui 28 V, Ii 93 mA, Pi 0.66 W, Ci 1.1 nF and Li 0.

Technical specifications

Measuring principlemicro-fuel cell
Rangesingle, 0-10 ppm up to 0-25 %
Accuracy±1 % of span; ±1 ppm below 0-100 ppm
Response time T9015 s; 40 s below 0-100 ppm
Output4-20 mA, two-wire loop
Supply9-24 V DC, loop-powered
DisplayLCD, 4.5 digit
Sample flow1-2 SCFH (0.5-1 SLPM)
Operating temperature0 °C to 50 °C
EnclosureNEMA-4 (IP66)
Cell compartment316 stainless steel
Hazardous area ratingII 1G Ex ia IIC T4 Ga; FM/FMc Class I Div 1, Div 2
Cable2 x 22 AWG, screened, 610 mm

Request a price and lead time

INSTATRANS / XD Intrinsically Safe O2 Transmitter, 4-20 mA, 0-10 ppm up to 0-25 %. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the lowest range it can be set to?

0-10 ppm, with 0-25 % O2 as the widest setting. Below 0-100 ppm the accuracy is ±1 ppm and T90 is 40 s.

Does it need a separate power supply?

No. It is powered from the 4-20 mA loop at 9-24 V DC, so two wires are enough.

Can it go into a Zone 0 area?

Yes, it is marked II 1G Ex ia IIC T4 Ga, and carries FM/FMc approval for Class I Division 1 and 2 in North America.