Filter Alert™ Differential Pressure Filter Monitor with LED Status Ring, up to 25 in WC
A light-switch-sized differential pressure monitor that tells maintenance staff at a glance whether an air handler filter is clean, nearly loaded or due for replacement, while feeding the same pressure value to the building management system. Hospitals, data centres, laboratories and cleanrooms are typical sites.
- Transducer range
- 0–1; 0–2.5; 0–3; 0–5; 0–10; 0–25 in WC
- Accuracy
- ±1.0% FS (standard); ±0.5% FS (option)
- Hysteresis
- ±0.10% FS
- Long-term drift
- ±0.5% FS a year
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Walk-by filter inspections take time, and most of them find nothing wrong. This unit replaces them with a coloured light ring: steady green, yellow when the filter is approaching its limit and red once replacement is due. The ring stands 11 mm proud of the faceplate, so it can be read from the side at 90° or from more than 50 feet down a corridor. A 128x160 RGB screen with LED backlighting shows the actual reading in inches of water column or Pa, and the thresholds are set numerically.
Wiring is simple. Supply is 24 V AC (±10%) or 24 V DC (18–32), drawing 1 W in normal running and 2 W peak. The analogue output is selectable between 4–20 mA, 0–5 V and 0–10 V for trending or alarms in the BMS, and 18–24 AWG stranded twisted-pair cable lands on removable screw terminals.
Six transducer spans are listed, the smallest 0–1 in WC and the largest 0–25 in WC, with 2.5, 3, 5 and 10 in WC in between. Out of the box the error stays within ±1.0% FS; a tighter ±0.5% FS grade can be ordered. Further figures: hysteresis ±0.10% FS, repeatability within 0.13% FS, drift no more than ±0.5% FS a year. The process gas must be air or another gas that neither conducts nor can explode, and static overpressure up to ±1 PSI is tolerated. Zero can be reset with a single press-and-hold, without removing the device.
Four mounting routes exist: a single-gang electrical box, a 2 in diameter cut-out, an existing DP gauge position using the conversion plate, or surface mounting. The faceplate comes in portrait or landscape orientation. The housing is UL94 V-0 fire-retardant plastic rated IP54, for 0–50 °C at 5–95% RH non-condensing, and storage from −30 °C to +70 °C. It carries CE and RoHS marking.
Technical specifications
| Transducer range | 0–1; 0–2.5; 0–3; 0–5; 0–10; 0–25 in WC |
|---|---|
| Accuracy | ±1.0% FS (standard); ±0.5% FS (option) |
| Hysteresis | ±0.10% FS |
| Long-term drift | ±0.5% FS a year |
| Overpressure | ±1 PSI |
| Media | air; gases that are non-conductive and non-explosive |
| Analogue output | 4–20 mA, 0–5 V or 0–10 V |
| Supply | 24 V AC (±10%) or 24 V DC (18–32) |
| Consumption | 1 W typical, 2 W max. |
| Indication | green/yellow/red light ring; 128x160 RGB display |
| Units | in WC or Pa |
| Operating temperature | 0–50 °C |
| Humidity | 5–95% RH non-condensing |
| Housing, protection | UL94 V-0 plastic, IP54 |
Request a price and lead time
Filter Alert™ Differential Pressure Filter Monitor with LED Status Ring, up to 25 in WC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which pressure ranges can be ordered?
Six transducer ranges: 0–1, 0–2.5, 0–3, 0–5, 0–10 and 0–25 in WC, with the display set to in WC or Pa.
How does it connect to the building management system?
Through a selectable 4–20 mA, 0–5 V or 0–10 V analogue output, wired with 18–24 AWG twisted pair to removable screw terminals.
Can it replace an existing DP gauge?
Yes, a conversion plate kit fits existing flush-mount DP gauge positions, and a separate kit covers surface mounting.
Similar equipment from other manufacturers