EZ-ZONE® RM Modular DIN-Rail Controllers, up to 152 Loops and 256 Monitor Points
A family of DIN-rail modules that can be combined freely to build anything from a single loop up to 152 control and limit loops, with as many as 256 monitored points. Modules run on their own or as one system sharing inputs, outputs and function blocks.
- Control/limit loops
- up to 152/192
- Monitor points
- up to 256
- Alarms
- up to 24 per module
- Maximum output
- 15 A
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Building a system starts with choosing modules. The range covers a combined control, monitoring and over/under-temperature limit module, high-density control and high-density limit modules, an I/O expansion module, a high-density monitor/scanner, a module for fibre optic temperature sensors, an EtherCAT® module, and an access module for data logging and field communications. Any mix can be connected and then configured in COMPOSER® software.
Beyond PID, each system can run counters, timers, maths, compare and logic blocks, so interlocks and simple sequences need not sit in a separate PLC. A high-speed backplane links the modules to the manufacturer's panel controllers and power controllers, removing discrete wiring between each heater's temperature and power control and giving access to diagnostic data from all three.
Each module handles up to 24 alarms. TRU-TUNE®+ adaptive tuning, setpoint profiling, remote limit reset and outputs up to 15 A are available, and the network options are Standard Bus, Modbus® RTU, Modbus® TCP, EtherNet/IP™ and EtherCAT®. An optional RUI display with 21 mm characters can be added for local viewing.
The polycarbonate housings carry double or reinforced insulation, accept either AC or DC supply and operate from -18°C to 65°C. Approvals include UL®, CSA, CE, RoHS, W.E.E.E., FM for the limit function and SEMI F47-0200, while selected models are listed for Class 1, Division II, Groups A, B, C and D under ANSI/ISA 12.12.01-2007.
The older EZ-ZONE RMA access module is flagged as not for new designs; RMA PLUS™ takes its place.
Technical specifications
| Control/limit loops | up to 152/192 |
|---|---|
| Monitor points | up to 256 |
| Alarms | up to 24 per module |
| Maximum output | 15 A |
| Adaptive tuning | TRU-TUNE®+ |
| Profiling | yes |
| Protocols | Standard Bus, Modbus® RTU, Modbus® TCP, EtherNet/IP™, EtherCAT® |
| Mounting | DIN rail |
| RUI display (option) | 21 mm character height |
| Operating temperature | -18°C to 65°C |
| Configuration | COMPOSER® software |
| Approvals | UL®, CSA, CE, RoHS, W.E.E.E., FM (limit), SEMI F47-0200, Class 1 Div. 2 (selected models) |
Request a price and lead time
EZ-ZONE® RM Modular DIN-Rail Controllers, up to 152 Loops and 256 Monitor Points. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How large can an EZ-ZONE® RM system grow?
From one loop up to 152 control and limit loops, with up to 256 monitor points in a single system.
Which fieldbuses are supported?
Standard Bus, Modbus® RTU, Modbus® TCP and EtherNet/IP™, plus EtherCAT® through a dedicated module.
Should the EZ-ZONE RMA module be used on a new project?
No. The RMA access module is marked as not for new designs, and RMA PLUS™ should be specified instead.
Similar equipment from other manufacturers