EXACTSENSE exhaust gas thermocouple for diesel aftertreatment, -40 to 1200°C
A thermocouple sensor that reports exhaust gas temperature to the engine control unit of diesel aftertreatment systems. On-board electronics deliver a signal the ECU can read directly, and up to three sensing points share one housing.
- Type
- Exhaust gas temperature thermocouple
- Temperature range
- -40 to 1200°C
- Outside diameter
- 2.1–4.8 mm (0.083–0.188 in.)
- Probe length
- Up to 200 mm
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Aftertreatment calibration depends on knowing exhaust temperature quickly and correctly, and that is the job EXACTSENSE was built for. It targets tough global emissions limits on medium and heavy-duty road vehicles and on off-road machinery in construction, mining, agriculture, marine and rail locomotive service.
The signal side is what sets it apart. Electronics inside a moulded connector housing turn the thermocouple output into a form the ECU accepts: CAN J1939, PWM, LIN or analogue 0-5V. Up to three sensing points can share one electronic housing, saving ECU I/O and leaving room for extra sensors. Integration also brings advanced diagnostic messages and better accuracy.
At the hot end sits a WATCOUPLE thermocouple, chosen for stability and long life at high temperature and also suited to burner, flame and turbo positions. Compacted mineral insulated construction allows a closed tip, and the tapered tip shortens response time. The operating range is -40 to 1200°C, outside diameter 2.1 to 4.8 mm (0.083 to 0.188 in.), and probe lengths reach 200 mm for large pipes that need deep immersion.
A set of standard options lets engine builders match the sensor to their own requirements.
Technical specifications
| Type | Exhaust gas temperature thermocouple |
|---|---|
| Temperature range | -40 to 1200°C |
| Outside diameter | 2.1–4.8 mm (0.083–0.188 in.) |
| Probe length | Up to 200 mm |
| Output signals | CAN J1939, PWM, LIN, analogue 0-5V |
| Sensing points per housing | Up to three |
| Sensing element | WATCOUPLE thermocouple, mineral insulated |
| Tip | Closed, tapered |
| Application | Diesel engine aftertreatment |
Request a price and lead time
EXACTSENSE exhaust gas thermocouple for diesel aftertreatment, -40 to 1200°C. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which output signals are available?
CAN J1939, PWM, LIN and analogue 0-5V, for direct connection to the ECU.
How many sensing points can share one housing?
Up to three sensing points per electronic housing.
What probe lengths can be supplied?
Probes up to 200 mm long are available for large pipes requiring deep immersion.