International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

EPower Modular SCR Power Controller, 100 A to 630 A Power Modules, up to Four Loops

A modular thyristor power controller for electric heating: one driver module runs as many as four power modules, each an independent control loop. Typical homes are glass, heat-treatment and vacuum furnaces, induction heating and large extruders.

Type
modular thyristor (SCR) power controller
Power module current
100 A to 630 A
Power modules per driver
up to 4 (up to 4 independent loops)
Control type
1 phase; 2, 3, 4 × 1 phase; 2 phase; 2 × 2 phase; 3 phase

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Electric furnaces and heater banks are where EPower earns its keep. Glass melting, heat treatment, high-temperature and vacuum furnaces, induction heating, multi-channel heaters, large extruders and food processing lines are the applications the manufacturer lists. A separate cabinet-built version is offered to replace legacy analogue thyristor supplies and variable reactance transformers (VRT) on heat-treatment furnaces.

Commissioning starts at the integral front display, where the QuickStart routine walks the engineer through the basic set-up in a few steps. The QuickStart code can be quoted on the order so the unit arrives already configured. Deeper work is done in PC configuration software with a graphical wiring editor; a finished configuration can be saved and cloned onto other units.

Hardware is split into a driver module and one to four power modules, with current ratings from 100 A to 630 A. Control type is chosen in software: single phase, two, three or four independent single-phase channels, two-phase, two lots of two-phase, or true three-phase. Load wiring may be single phase, star, star with neutral, delta or open delta. Because firing mode, load type, phases and control are set in the common driver module, one spares kit covers many builds.

Firing modes are phase angle, half cycle, burst firing, fixed modulation period and logic. Feedback can be V², I², true power, RMS load voltage, RMS load current or open loop. Supported loads: plain resistive, complex resistive, inductive such as a transformer primary, and short-wave infrared emitters.

Option boards fitted to the driver add networking (RS485 Modbus RTU, Modbus TCP, Profibus, DeviceNet, CC-Link, EtherNet/IP, PROFINET) and up to three extra I/O cards with analogue inputs and outputs, digital I/O and relays. Predictive Load Management spreads demand across several machines to cut peak charges. The LTC option, for single-phase units only, drives multi-tap transformers without raising harmonics or lowering power factor, and up to 5 scalable energy counters are available over comms and on screen.

Technical specifications

Typemodular thyristor (SCR) power controller
Power module current100 A to 630 A
Power modules per driverup to 4 (up to 4 independent loops)
Control type1 phase; 2, 3, 4 × 1 phase; 2 phase; 2 × 2 phase; 3 phase
Load configurationsingle phase, star, star with neutral, delta, open delta
Firing modesphase angle, half cycle, burst firing, fixed modulation period, logic
FeedbackV², I², true power, RMS voltage, RMS current, open loop
Load typesresistive, complex resistive, inductive (transformer), short-wave infrared
CommunicationsRS485 Modbus RTU, Modbus TCP, Profibus, DeviceNet, CC-Link, EtherNet/IP, PROFINET
Additional I/O boardsup to 3
Energy countersup to 5
OptionsPredictive Load Management, LTC (single-phase units only)

Request a price and lead time

EPower Modular SCR Power Controller, 100 A to 630 A Power Modules, up to Four Loops. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many loops can one EPower handle?

A single driver module supports up to four power modules, giving up to four independent control loops.

What current ratings are available?

Power modules cover 100 A to 630 A, chosen to suit the load current of each loop.

Can it drive a load through a transformer?

Yes. Inductive transformer loads are a standard load type, and single-phase units can take the LTC option for multi-tap transformers.