CDQC CO2 purity monitoring system with modular gas analysers in a NEMA-12 enclosure
CDQC is a factory-built analyser package that watches food-grade carbon dioxide for trace contaminants around the clock. It suits CO2 recovery from fermentation, ethanol and ammonia plants, where gas goes on to beverage carbonation, dry ice or liquefied storage.
- Duty
- impurity monitoring in CO2
- CO2 purity (typical limit)
- 99.9% min
- Enclosure
- NEMA-12, 1 or 2 bays, steel with powder finish, windows
- Tubing and fittings
- 316 stainless steel
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Inside the enclosure, each contaminant has its own instrument. An ultrafast gas chromatograph from the 4000 Series handles benzene, acetaldehyde and methanol; GFC-7001T covers carbon monoxide; 8800A reads trace moisture; 9110T and 9130T deal with nitrogen oxides and ammonia; 3000TA measures oxygen; 4020 gives total hydrocarbons and 4040 splits methane from non-methane; 6200T reports total sulphur. Buyers specify only the measurements their contract calls for, so the cabinet holds nothing superfluous.
Why so many? Raw gas from fermentation and chemical sources carries compounds that spoil taste and odour or create a health risk. Typical limits sit at 0.2 ppm acetaldehyde, 20 ppb benzene, 10 ppm CO, 20 ppm moisture, 30 ppm oxygen and 0.1 ppm total sulphur, against a purity of at least 99.9% CO2. Actual targets vary with the customer and the source of the gas.
The housing is a NEMA-12 steel cabinet with a powder finish, one or two bays wide, with glazed doors so operators can read every display, flow and pressure setting without opening up. Wetted tubing is grade 316 stainless, with sulphur-treated runs where trace sulphur is measured. Sample conditioning, utility gas connections and built-in solenoid valves for calibration gas come as standard, and calibration runs either remotely or automatically. A Model 701 zero air generator can be fitted to feed the flame ionisation instruments.
Options include multi-stream switching through VB Series valve boxes, a stainless enclosure with NEMA or IP rating, and climate control. The data acquisition unit runs Windows CE on a PXA270 processor (32-bit, 520 MHz), logs and trends readings, raises alarms, applies statistical process control and prints certificates of analysis. Plant links are Profibus-DP, OPC, Modbus-RTU or Modbus-TCP.
Technical specifications
| Duty | impurity monitoring in CO2 |
|---|---|
| CO2 purity (typical limit) | 99.9% min |
| Enclosure | NEMA-12, 1 or 2 bays, steel with powder finish, windows |
| Tubing and fittings | 316 stainless steel |
| Gas connections | 1/4 in tube fittings |
| Electrical entries | FNPT (NPT or metric) |
| Calibration | remote and automatic |
| Analysers | 4000 Series, GFC-7001T, 8800A, 9110T, 9130T, 3000TA, 4020, 4040, 6200T |
| Protocols | Profibus-DP, OPC, Modbus-RTU, Modbus-TCP |
| Interfaces | Ethernet, RS485 |
| Data acquisition | Windows CE, PXA270, 32-bit, 520 MHz |
Request a price and lead time
CDQC CO2 purity monitoring system with modular gas analysers in a NEMA-12 enclosure. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which contaminants can the package measure?
Acetaldehyde, benzene, methanol, CO, moisture, nitrogen oxides, ammonia, oxygen, total hydrocarbons with a methane/non-methane split, and total sulphur. You choose the analysers to match your own specification.
Can one system sample several points?
Yes. Optional VB Series valve boxes switch streams in sequence on individual timers, driven by Profibus-DP, discrete signals or a manual push-button.
What enclosure ratings are offered?
As standard you get a steel NEMA-12 cabinet, powder finished, in one or two bays with glazed doors. A stainless cabinet with NEMA or IP rating and climate control is available as an option.