International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

9110T / 9110TH Chemiluminescence NOx Analyser for NO, NO2 and NOx, 0-50 ppb to 0-5,000 ppm

A nitrogen oxides analyser working on gas-phase chemiluminescence, aimed at ambient air stations, emission monitoring and process gas. The 9110T handles low-level work from 0-50 ppb to 0-20,000 ppb, while the 9110TH is the high-concentration build at 0-5 ppm to 0-5,000 ppm.

Measuring principle
chemiluminescence
Components
NO, NO2, NOx; O2 optional
Ranges 9110T
0-50 ppb to 0-20,000 ppb
Ranges 9110TH
0-5 ppm to 0-5,000 ppm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

On the 9110T the lower detectable limit is 0.4 ppb, zero noise stays under 0.2 ppb RMS and zero drift under 0.5 ppb per 24 hours, with span drift below 0.5 % of full scale over the same period. Lag time is 20 s, rise and fall to 95 % take under 60 s, linearity is 1 % of full scale and precision 0.5 % of reading above 50 ppb. Sample flow is 500 cm3/min ±10 % on the 9110T and 290 cm3/min on the 9110TH.

NO, NO2 and NOx ranges are set independently, auto-ranging between two ranges is supported, and readings can be shown in ppb, ppm, μg/m3 or mg/m3. A paramagnetic oxygen sensor can be added as an option.

Applications span ambient air monitoring, dilution and extractive CEM, stack testing, cement kiln inlet measurement for clinker quality, thermal DeNOx, CO2 purity analysis and general process control. The instrument holds EPA equivalent method designation RFNA-1104-099 and MCERTS certification, and complies with IEC 61010-1 and EN 61326-1.

Connectivity is generous as standard: 10/100Base-T Ethernet, two RS-232 ports (300-115,200 baud), two USB device ports, eight opto-isolated status outputs, six opto-isolated control inputs and four analogue outputs selectable at 10 V, 5 V, 1 V or 0.1 V. Options add RS485, eight 0-10 V analogue inputs, four alarm outputs, three 4-20 mA current outputs and multidrop RS232. Set-up and readings are handled on a graphical touchscreen.

The analyser runs from 100-120 V or 220-240 V mains at 50/60 Hz and is specified for 5 °C to 40 °C ambient. It measures 178 x 432 x 597 mm and weighs 18 kg, with the external pump adding 7 kg; internal pump versions are also offered. Calibration is either automatic with AutoCal or manual via zero and span valves.

Technical specifications

Measuring principlechemiluminescence
ComponentsNO, NO2, NOx; O2 optional
Ranges 9110T0-50 ppb to 0-20,000 ppb
Ranges 9110TH0-5 ppm to 0-5,000 ppm
Lower detectable limit (9110T)0.4 ppb
Zero noise (9110T)under 0.2 ppb RMS
Zero drift (9110T)under 0.5 ppb per 24 h
Rise/fall timeunder 60 s to 95 %
Linearity1 % of full scale
Sample flow500 cm3/min (9110T); 290 cm3/min (9110TH)
Analogue outputs10 V, 5 V, 1 V, 0.1 V
InterfacesEthernet, 2 x RS-232, 2 x USB
Supply100-120 V, 220-240 V, 50/60 Hz
Operating temperature5 °C to 40 °C
Dimensions, weight178 x 432 x 597 mm, 18 kg

Request a price and lead time

9110T / 9110TH Chemiluminescence NOx Analyser for NO, NO2 and NOx, 0-50 ppb to 0-5,000 ppm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the 9110T and 9110TH differ?

The 9110T is for low concentrations, 0-50 ppb to 0-20,000 ppb with a 0.4 ppb detection limit; the 9110TH covers high concentrations from 0-5 ppm to 0-5,000 ppm.

Can it be used in emission monitoring systems?

Yes, in dilution and extractive CEM and stack testing; it carries EPA equivalent method designation RFNA-1104-099 and MCERTS certification.

How does it connect to a plant control system?

Ethernet, two RS-232 and two USB ports, status outputs and control inputs come as standard, with RS485 and three 4-20 mA outputs available as options.