8801A panel-mount moisture monitor, dewpoint -100 to 20°C, 4-20 mA output
A DIN-sized panel indicator paired with a remote nanopore sensor for measuring water vapour in gases. It reads dewpoint from -100 to 20°C, draws trends on screen and retransmits the value over an isolated 4-20 mA loop.
- Dewpoint range
- -100 to 20°C
- Accuracy
- ±2°C, temperature corrected
- Repeatability
- 0.8°C
- Response time
- 95% of step change in 3 min
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The sensing end is the 8801T probe, built around a nanopore structure. Water vapour molecules diffuse into the pores and the instrument counts what has entered; because the porous layer is thin, the inside and outside equilibrate quickly. That gives 95% of a step change within 3 minutes, 0.8°C repeatability and ±2°C accuracy with temperature correction. Sample flow should exceed 1 LPM. The probe arrives with a 3 metre cable on an M12 connector and a sintered stainless shield; a solid shield and an oxygen-cleaned sensor are also listed.
The display unit is an ABS housing for a DIN 43700 panel cutout of 5.39 by 2.67 in, 3 in deep, weighing 0.7 kg. Power detection is automatic, either 90-260 VAC at 47-440 Hz or 12-24 VDC at 10VA. Standard I/O covers an isolated 4-20 mA sink or source output plus alarm relays rated 3A, 250 VAC/30 VDC; RS-485/422 with Modbus ASCII and RTU is an extra. Readings can be shown as °C or °F dewpoint, ppmV, ppmW, vapour pressure, grams per cubic metre, or pounds of water per million standard cubic feet for natural gas.
Typical users are natural gas and petrochemical sites, industrial gas suppliers, power stations, heat treatment furnaces and compressed air dryers, as well as pharmaceutical, aerospace and medical facilities.
Electronics tolerate -40 to 85°C, with an operating span of -20 to 70°C and storage at -30 to 80°C. Calibration is NIST traceable, NEMA 12 gasketing can be supplied for the panel, and a virtual analyser for the PC, with spoken explanations, helps with training.
Technical specifications
| Dewpoint range | -100 to 20°C |
|---|---|
| Accuracy | ±2°C, temperature corrected |
| Repeatability | 0.8°C |
| Response time | 95% of step change in 3 min |
| Sample flow | > 1 LPM |
| Power supply | 90-260 VAC, 47-440 Hz or 12-24 VDC, 10VA |
| Analogue output | isolated 4-20 mA, sink or source |
| Alarm relays | 3A, 250 VAC/30 VDC |
| Digital interface (option) | RS-485/422, Modbus ASCII and RTU |
| Mounting | panel, DIN 43700, cutout 5.39 x 2.67 in, 3 in deep |
| Weight | 0.7 kg |
| Operating temperature | -20 to 70°C |
| Insulation resistance | > 100 MΩ at 500 VDC |
Request a price and lead time
8801A panel-mount moisture monitor, dewpoint -100 to 20°C, 4-20 mA output. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which units can the display show?
Dewpoint in °C or °F, ppmV, ppmW, water vapour pressure, grams per cubic metre, and pounds of water per million standard cubic feet for natural gas. The 4-20 mA output is linear to whichever unit you pick.
Is there a digital link to the DCS?
Order code 8801A.D.0 adds isolated RS-485/422 with Modbus ASCII or RTU. The isolated 4-20 mA output and alarm relays are fitted as standard.
What sensor options exist?
The standard dewpoint probe has a sintered stainless steel shield. A solid shield (code S) and an oxygen-cleaned sensor (code O2) can be ordered instead.
Similar equipment from other manufacturers