A low-profile 19-inch rack analyser that measures as many as five gas components continuously using non-dispersive infrared, with a paramagnetic or fuel cell channel for oxygen. It is aimed at combustion control, process gas streams and emissions monitoring.

Measuring principle
NDIR; O2 paramagnetic or fuel cell
Components
up to 5 at once
NO
0–200 to 0–5000 ppm
SO2
0–200 ppm to 0–10%

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Ranges are chosen per component. NO runs from 0–200 up to 0–5000 ppm, SO2 from 0–200 ppm up to 0–10%, CO2 from 0–100 ppm up to 0–100%, CO from 0–200 ppm up to 0–100% and CH4 from 0–500 ppm up to 0–100%. Oxygen spans 0–10% to 0–25% on the fuel cell, or 0–5% to 0–100% on the paramagnetic sensor.

In the 7500Z the optics are single beam and single path; the 7600Z builds in its own sample switching. Repeatability is ±0.5% FS, linearity 1% FS before the optional atmospheric pressure correction, and span drift ±2% FS per week. Electrical response is 1 to 15 s, or 10 to 30 s once the time to flush the cell is included.

Plants that use it include boilers and incinerators, blast furnaces, steel converters, heat treatment and sintering furnaces, coke ovens, flue gas desulphurisation and denitration units, refineries and petrochemical sites. Biogas and landfill gas, ammonia and fertiliser streams, produce storage, fermentation, CEMS installations and research labs are other common duties.

Wetted parts are a stainless steel 304 cell, chloroprene rubber seals and calcium fluoride windows, with 1/4 NPT or Rc1/4 gas ports. Sample pressure must stay below 1.5 psig, venting to atmosphere, at 0.5 SLPM. Ambient range is −5 °C to 45 °C, and the mains input is 100–240 V ac, 50/60 Hz, 100 VA maximum.

Each component has its own isolated 4–20 mA output, with 0–1 V dc as an option, and data are available over RS-485 MODBUS RTU. Form-C contacts serve one system alarm and two concentration alarms. The rack chassis is 3U high at 483 × 133 × 382 mm. Wall-mounted 7500ZB / 7600ZB versions come in a NEMA-4 box of 610 × 610 × 305 mm, and with purging the analyser may be installed in Zone 1 or Zone 2 areas.

Technical specifications

Measuring principleNDIR; O2 paramagnetic or fuel cell
Componentsup to 5 at once
NO0–200 to 0–5000 ppm
SO20–200 ppm to 0–10%
CO20–100 ppm to 0–100%
CO0–200 ppm to 0–100%
CH40–500 ppm to 0–100%
O20–10% to 0–25% (fuel cell); 0–5% to 0–100% (paramagnetic)
Repeatability±0.5% FS
Response1–15 s electrical; 10–30 s incl. gas replacement
Sample flow / pressure0.5 SLPM / <1.5 psig
Operating temperature−5 °C to 45 °C
Outputsisolated 4–20 mA per component; RS-485 MODBUS RTU
Power supply100–240 V ac, 50/60 Hz, 100 VA
Dimensions (rack)483 × 133 × 382 mm

Request a price and lead time

7500ZA / 7600ZA Infrared Multi-Gas Analysers, 3U Rack, Up to Five Components. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many gases can one analyser read?

Up to five components at the same time, chosen from CO, CO2, NO, SO2, CH4 and O2, each with its own 4–20 mA output.

What is the difference between the 7600ZA and 7500ZA?

The 7600ZA includes an internal sample switching system, while the 7500ZA has single beam, single path optics without switching.

Can it be used in a hazardous area?

Yes, when purged it is suitable for Zone 1 or Zone 2 locations.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides