International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

555 1/4 DIN Chlorination/Dechlorination Controller, 2 inputs, 2 x 4-20 mA

The 555 is a UL approved 1/4 DIN controller for chlorination and dechlorination of potable and waste water. It handles flow proportional, residual and compound loop control with lag times, plus dechlorination with sulfur dioxide. The supply is 90-250 Vac and the front panel is NEMA 4X.

Model
555-21120B0000
Function
Chlorination and dechlorination controller
Control strategies
Flow pacing, residual, compound loop with lag times, SO2 dechlorination
Inputs
2 programmable: mV, current, voltage

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 555 is a UL approved 1/4 DIN controller built for automatic, accurate control of chlorine in potable and waste water. It is set up for flow proportional control, residual control, compound loop control with lag times, or dechlorination with sulfur dioxide.

The strategy is chosen from the menu. Flow pacing positions a chlorine or sulfur dioxide valve in direct proportion to the water flow rate. The user sets a dosage from 0% to 400%, the percentage of gas flow to water flow. Chlorination and dechlorination can run together from the same water flow. Residual control has fixed lag time compensation, and compound loop control has fixed and variable lag time compensation. A backup strategy can be selected for sensor failure. Optional high and low vacuum alarm inputs close the control valve if the alarm stays closed for over 30 seconds, and the display shows NO GAS.

Version 555-21120B0000 has two programmable inputs for mV, current or voltage. The outputs are two 4-20 mA analogue channels and two 5 A mechanical relays, and the supply is universal AC, 90-250 Vac. The remote setpoint option is fitted. Square root linearisation is selectable, as are alarms for high, low, deviation, rate-of-change, latching sequence, relay action and customised messages. Security is user-definable.

The front panel is NEMA 4X. The vacuum fluorescent display has a large five-digit upper readout and two nine-character alphanumeric lines, and the rubber keys are backlit. The controller fits a standard 1/4 DIN cutout, for panel thickness of 0.06 to 0.275 in., and measures 182.37 x 95.76 mm.

Technical specifications

Model555-21120B0000
FunctionChlorination and dechlorination controller
Control strategiesFlow pacing, residual, compound loop with lag times, SO2 dechlorination
Inputs2 programmable: mV, current, voltage
Analogue outputs2 x 4-20 mA
Relay outputs2 mechanical relays, 5 A
PowerUniversal AC, 90-250 V
Option fittedRemote setpoint
Dosage setting0% to 400%
Housing1/4 DIN panel mount, NEMA 4X front
DisplayVacuum fluorescent, five-digit readout and 2 lines of 9 characters
Dimensions182.37 x 95.76 mm
Panel thickness0.06 to 0.275 in.
ApprovalsUL, RoHS

Part numbers

Show all part numbers (1)

555-21120B0000

How it compares with similar models

Parameter555 1/4 DIN Chlorination/Dechlorination Controller, 2 inputs, 2 x 4-20 mA545 1/4 DIN Dual Loop Process Controller, 2 universal inputs, 2 x 4-20 mA outputs532 1/4 DIN Auto/Manual Station, manual backup for control loops535-PROFILE 1/4 DIN Process Controller with profile and recipe control
FunctionChlorination and dechlorination controllerDual-loop PID controller, cascade, ratio, feed forwardAuto/Manual backup stationSingle loop controller, profile or recipe control
Inputs2 programmable: mV, current, voltage2 programmable universal: RTD, T/C, mV, current, voltage—2 programmable universal: RTD, T/C, mV, current, voltage
Relay outputs2 mechanical relays, 5 A2 mechanical relays, 5 A3 mechanical relays, 5 A—
Housing1/4 DIN panel mount, NEMA 4X front1/4 DIN panel mount, NEMA 4X front1/4 DIN panel mount, NEMA 4X front1/4 DIN panel mount, NEMA 4X
DisplayVacuum fluorescent, five-digit readout and 2 lines of 9 charactersVacuum fluorescent, 3 linesVacuum fluorescent, five-digit field and two lines of 9 characters—

Request a price and lead time

555 1/4 DIN Chlorination/Dechlorination Controller, 2 inputs, 2 x 4-20 mA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which chlorine control strategies does the 555 offer?

Flow proportional, residual, compound loop with lag times, and dechlorination with sulfur dioxide.

What dosage range can be set?

From 0% to 400% (gas flow as a percentage of water flow), for both chlorination and dechlorination.

What inputs, outputs and supply does 555-21120B0000 have?

Two programmable inputs (mV, current, voltage), two 4-20 mA outputs, two 5 A relays and a 90-250 Vac supply.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides