International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

3190 / 3290 Panel Oxygen Analysers for ppm and Percent O2 in Inert Gases

Two small panel instruments sharing one housing and one set of electronics. The 3190 handles oxygen at ppm level in nitrogen and other inert gases, while the 3290 reads percent oxygen from 0–1% up to 0–25%, with 0–100% as an option.

Models
3190 (trace O2), 3290 (percent O2)
3190 ranges
0–10 ppm and 0–1000 ppm, user span 10 ppm to 10,000 ppm
3290 ranges
0–1% to 0–25%, 0–100% optional
Calibration range
0–25%

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Where these analysers earn their keep is on wave solder and reflow ovens, glove boxes, nitrogen membrane and PSA skids, nitrogen generators, helium recovery and inert blanketing, as well as clean air systems in medical use.

Power can be taken from 10–36 V dc or from 100–240 V ac mains at 47–440 Hz, chosen by the user. The housing is 71.4 × 152.4 × 72.9 mm for panel fitting, the front carries a NEMA-4 rating and ambient range is 0–50 °C. Indoor, non-hazardous locations only.

The 3190 is the ppm instrument. Its standard scales are 0–10 ppm and 0–1000 ppm, a user span may be set anywhere between 10 ppm and 10,000 ppm, and 0–25% is reserved for calibrating on air. Error is ±1% FS under stable temperature. With a fuel cell the signal reaches 90% within 45 s at 25 °C; a zirconium oxide sensor (3190Z) is quicker still. A class B-2 cell covers scales below 0–200 ppm, and an A-2C cell is offered where CO2 is present in the background.

The 3290 uses an E-2 cell for percent work, reaching 90% in under 10 s with ±2% FS error at stable temperature.

Both share an LED readout, a non-isolated 4–20 mA and 0–10 V dc concentration signal referenced to negative ground, and a separate 0–10 V dc output that identifies the active range. Two adjustable relays handle high and low limits and a third flags a sensor calibration fault; every alarm is failsafe. Glove box builders can order the 3190GB or 3290GB, supplied with a mounting plate and a hermetically sealed cable connector.

Technical specifications

Models3190 (trace O2), 3290 (percent O2)
3190 ranges0–10 ppm and 0–1000 ppm, user span 10 ppm to 10,000 ppm
3290 ranges0–1% to 0–25%, 0–100% optional
Calibration range0–25%
3190 accuracy±1% FS at stable temperature
90% response at 25 °C (3190)<45 s with fuel cell
3190 sensorclass B-2; A-2C or zirconium oxide optional
DisplayLED
Output signal4–20 mA and 0–10 V dc, negative ground, non-isolated
Range identification0–10 V dc
Alarmshigh limit, low limit, sensor calibration fault
Power supply10–36 V dc or 100–240 V ac, 47–440 Hz
Operating temperature0–50 °C
Dimensions (H × W × D)71.4 × 152.4 × 72.9 mm

Request a price and lead time

3190 / 3290 Panel Oxygen Analysers for ppm and Percent O2 in Inert Gases. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which model suits a nitrogen generator outlet?

For ppm-level oxygen choose the 3190 with its 0–10 ppm and 0–1000 ppm scales. If residual oxygen is in the percent region, the 3290 with 0–1% to 0–25% fits better.

Can the unit run from a dc supply?

Yes. It accepts either 10–36 V dc or 100–240 V ac at 47–440 Hz.

Is a zirconia sensor available?

Yes, the 3190Z uses a zirconium oxide sensor and responds faster than the fuel cell version.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides