3020M Flameproof Paramagnetic O2 Analyser, Ranges 0-5 % to 0-100 %
A wall-mounted paramagnetic oxygen analyser for process gas streams in hazardous areas. The ATEX/IECEx build is marked II 2G Ex db IIB+H2 T6 Gb, and the North American build is UL and CSA listed for Class I Division 1 locations.
- Measuring principle
- paramagnetic
- Ranges
- 3 user-set, 0-5 % to 0-100 %
- Calibration range
- 0-25 %
- Accuracy
- ±1 % FS at steady temperature; ±5 % FS over operating range
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Oxygen in process gas is watched for three reasons: control, product quality and safety. That is where this analyser earns its place, on ethylbenzene and styrene units, PTA, phenol and cumene, polyethylene and polystyrene plants, ethylene oxide and glycol, ammonia and urea fertiliser, refinery FCC and flare gas, marine vapour recovery, inert gas blanketing and air separation.
Measurement is paramagnetic, with wetted parts in glass, steel, gold, Viton, acrylic glass and epoxy resin. The user sets up three ranges, typically somewhere between 0-5 % and 0-100 %, and autoranging reports the active range on a dedicated ID output. Calibration range is 0-25 %. Accuracy is ±1 % FS when ambient temperature is steady and ±5 % FS across the whole operating temperature band; linearity is 0.1 % O2, repeatability 0.1 % FS, and the reading reaches 90 % of full scale in under 10 seconds at 25 °C.
Readings show on a 5 digit red LED display, with set-up on a 2 line, 20 character vacuum fluorescent screen. Signals leave the instrument as a pair of isolated 4-20 mA outputs and a pair of 0-1 V DC outputs, together with a system failure contact, two adjustable concentration alarms and an RS-232C port.
For European sites the ATEX/IECEx version is rated IP66 for 0-50 °C ambient, runs from 115 or 230 V AC, 50/60 Hz at up to 310 W, and handles oxygen up to 20.9 %; it must not be used on oxygen-enriched gas above 21 %. Sensor inlet pressure is limited to 6 kPa and sample flow to 1100 SCCM. The enclosure carries an M6 earthing bolt underneath, cable entries are 3/4 or 1 inch NPT, and sample lines connect with 1/4 inch or 6 mm fittings. Overall size is 387.35 x 651 x 279.4 mm.
Technical specifications
| Measuring principle | paramagnetic |
|---|---|
| Ranges | 3 user-set, 0-5 % to 0-100 % |
| Calibration range | 0-25 % |
| Accuracy | ±1 % FS at steady temperature; ±5 % FS over operating range |
| Response time | 90 % FS in under 10 s at 25 °C |
| Linearity | 0.1 % O2 |
| Analogue outputs | 2 x 0-1 V DC, 2 x 4-20 mA, isolated |
| Alarms | system failure + 2 concentration alarms |
| Interface | RS-232C |
| Supply | 100-240 V AC, 50/60 Hz, 70 W |
| Hazardous area rating | Class I Division 1, gas groups B, C, D; II 2G Ex db IIB+H2 T6 Gb |
| Enclosure | NEMA 4/7; IP66 (ATEX) |
| Sample connections | 1/4 inch or 6 mm |
| Dimensions | 387.35 x 651 x 279.4 mm |
Request a price and lead time
3020M Flameproof Paramagnetic O2 Analyser, Ranges 0-5 % to 0-100 %. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the ATEX version measure up to 100 % oxygen?
No. The ATEX/IECEx build is for oxygen up to 20.9 % and must not see gas enriched above 21 % O2; the wider ranges apply to the standard build.
How does it connect to a DCS?
Through isolated 4-20 mA and 0-1 V DC outputs (two of each), relay contacts for system failure and two concentration alarms, plus an RS-232C serial port.
What hazardous area approvals does it carry?
UL and CSA listing for Class I Division 1, gas groups B, C and D in North America, and ATEX/IECEx marking II 2G Ex db IIB+H2 T6 Gb for European and international sites.