3010PBC / 3010TBC Oxygen Analysers with Micro-Fuel Cell Sensor

Two fixed oxygen analysers from the 3010 series, one for percent-level work and one for trace measurement in ppm. Both use an electrochemical micro-fuel cell and deliver a 4-20 mA signal through an isolated output module.

Models
3010PBC (percent), 3010TBC (trace)
Measuring principle
micro-fuel cell
Range (catalogue)
0-10 ppm (min), 0-9,999 ppm (max)
Calibration
0-25%

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The pair share a chassis but not a sensor. The 3010TBC is the trace model, fitted with a class L-2C micro-fuel cell (C6689-L2C), a trace preamplifier board C-62368A, back-panel interface board D-65295A and a B-66378 cell spacer for B-2C or A-2C sensors. The 3010PBC is the standard percent model, with a class B-1 cell (C6689-B1), percent preamplifier C-62368B and customer interface board D-65295B.

A micro-fuel cell is an electrochemical sensor whose output current follows the oxygen content of the sample gas. The catalogue gives measuring ranges from 0-10 ppm at the low end to 0-9,999 ppm at the high end, with calibration carried out within 0-25%.

The front panel board C-62371B and the interface board are common to both. The main computer board comes as C-73870C in standard form or, on the 3010PBC, as C-73870A with the 4-20 mA option, and the analogue signal is taken from an isolated I226 module. Supply circuits are protected by 1A, 250V, 5x20 mm slow-blow fuses.

The cell is a consumable, so most sites keep one in stock along with O-rings and fuses. Spares orders should quote the part number, the model and the instrument serial number.

Technical specifications

Models3010PBC (percent), 3010TBC (trace)
Measuring principlemicro-fuel cell
Range (catalogue)0-10 ppm (min), 0-9,999 ppm (max)
Calibration0-25%
Cell, 3010PBCC6689-B1, class B-1
Cell, 3010TBCC6689-L2C, class L-2C
Analogue output4-20 mA, isolated module I226
Main boardC-73870C (standard), C-73870A (4-20 mA option)
Fuse1A, 250V, 5x20 mm, slow-blow

Request a price and lead time

3010PBC / 3010TBC Oxygen Analysers with Micro-Fuel Cell Sensor. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What separates the 3010PBC from the 3010TBC?

The 3010PBC is the percent model with a C6689-B1 cell; the 3010TBC is for trace levels, with a C6689-L2C cell and its own C-62368A preamplifier.

What measuring range is available?

The catalogue lists 0-10 ppm minimum and 0-9,999 ppm maximum ranges, with calibration within 0-25%.

Which spares are worth holding?

A micro-fuel cell of the correct class, O-rings, 1A 250V 5x20 mm fuses and the I226 4-20 mA module.