3000MB Percent Oxygen Analyser with Paramagnetic Dumbbell Cell, 0–5 % up to 0–100 % O2
A microprocessor-based instrument for reading oxygen in process gases at percent level. Three user spans, automatic span changing and calibration on any span suit air separation, blanketing and reactor duties.
- Measuring principle
- paramagnetic
- Spans
- 3 user-set, 0–5 % up to 0–100 % O2, auto-ranging
- Linearity
- 0.1 % O2
- Calibration span
- 0–25 %
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Inside the sensing cell, two small spheres form a dumbbell hung in a non-uniform magnetic field. Oxygen pulls the dumbbell round; a mirror on it shifts a light beam between two photodiodes, and the current needed to drive it back to the null position is proportional to O2 concentration. Wetted parts are glass, steel, gold, fluoroelastomer, acrylic glass and epoxy resin.
Operators set three spans anywhere from 0–5 % to 0–100 % O2, with lower spans available, plus a 0–25 % calibration span. Every span is linear, so changing span does not call for recalibration.
Deviation from linearity stays within 0.1 % O2; repeatability is held to 0.1 % FS. Zero drift is 0.05 % O2 and span drift 1 % FS per month. Accuracy is ±1 % FS with steady ambient and ±5 % FS over the 0–45 °C operating band. A 90 % response arrives inside 10 s at 25 °C.
The sample should be non-condensing, at 0–50 °C, 5–20 psig and 1–2 SCFH, through 1/4 inch or 6 mm fittings. Two 0–1 V and two isolated 4–20 mA signals carry concentration and range ID; RS-232C allows remote zero and span; two concentration alarms and a system failure contact are fitted. Supply is 100–240 V AC, 50/60 Hz, 70 W maximum.
The basic unit is general purpose. The 3000MB-C adds separate zero and span ports with built-in valves and is FM-approved as non-purged equipment in Class 1, Division 2 areas; with a Y-purge it may be used in Division 1. On the 3000MB-M the 4–20 mA output is active. Typical users run air separation, chemical reactors, emissions checks, petrochemical units and gas quality laboratories.
Technical specifications
| Measuring principle | paramagnetic |
|---|---|
| Spans | 3 user-set, 0–5 % up to 0–100 % O2, auto-ranging |
| Linearity | 0.1 % O2 |
| Calibration span | 0–25 % |
| Repeatability | 0.1 % FS |
| Zero / span drift | 0.05 % O2 / 1 % FS per month |
| Accuracy | ±1 % FS at steady temperature; ±5 % FS over operating band |
| Response | 90 % in < 10 s at 25 °C |
| Operating temperature | 0–45 °C |
| Sample | 5–20 psig, 1–2 SCFH, 0–50 °C |
| Outputs | 2 × 0–1 V, 2 × 4–20 mA isolated; RS-232C |
| Supply | 100–240 V AC, 50/60 Hz, 70 W max |
| Size (W × H × D) | 11.81 × 20.28 × 8.9 inch |
| Versions | general purpose; 3000MB-C FM-approved, Class 1 Division 2 |
Request a price and lead time
3000MB Percent Oxygen Analyser with Paramagnetic Dumbbell Cell, 0–5 % up to 0–100 % O2. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How low can the 3000MB measure?
Typical spans run from 0–5 % to 0–100 % O2, and the manufacturer offers lower spans down to 0–1 %. All three user spans are linear.
Can it go into a classified area?
Yes, the 3000MB-C is FM-approved for Division 2 locations of Class 1 without purging. Division 1 calls for a Y-purged unit.
What sample conditions does it need?
Inlet pressure of 5–20 psig, flow of 1–2 SCFH, sample temperature 0–50 °C and no condensation at ambient temperature.
Similar equipment from other manufacturers