International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SIMA² master station for actuator control and supervision

SIMA² is a master station that controls and supervises actuators and other field devices over standardised fieldbus systems. Each unit takes up to 4 separate networks with up to 247 field devices per network, and has a 7” touchscreen and web server.

Type
Master station for actuator control and supervision
Fieldbus networks
up to 4 separate per station
Field devices per network
up to 247
Protocols to field devices
Modbus RTU, Profibus DP

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SIMA² master station sits between the host level and the field level of an installation. It sends operating commands to the actuators, collects their feedback signals and gathers diagnostic data from every connected device in one central function. Commissioning of both the actuators and the fieldbus network is simplified, and actuators can be operated manually from the station's own HMI without a DCS.

One station handles up to 4 separate fieldbus networks, each with up to 247 field devices. Towards the field devices it speaks Modbus RTU or Profibus DP; towards the DCS it uses Modbus RTU and/or Modbus TCP/IP. It also works as a gateway between different communication systems. Single-channel and redundant line and loop topologies are supported, together with hot standby redundancy of the system itself.

On the front and rear panels there are an integral 7” multi-touchscreen, an integrated web server, RS-485, Ethernet (RJ45), USB and an integral OPC UA server. The housing is made for installation in 19” rack systems.

Options include overvoltage protection for RS-485, digital inputs and outputs, alternative housings and project-specific control cabinet versions.

Technical specifications

TypeMaster station for actuator control and supervision
Fieldbus networksup to 4 separate per station
Field devices per networkup to 247
Protocols to field devicesModbus RTU, Profibus DP
Protocols to the DCSModbus RTU, Modbus TCP/IP
Topologiessingle-channel and redundant line and loop
System redundancyHot standby
Interfaces7” multi-touchscreen, web server, RS-485, Ethernet (RJ45), USB, OPC UA server
Housingfor 19” rack systems
OptionsRS-485 overvoltage protection, digital inputs and outputs, housing options, project-specific control cabinet

How it compares with similar models

ParameterSIMA² master station for actuator control and supervisionSVC/SVCR electric globe valve actuators with integral controls, 10–100 NmSVM/SVMR electric globe valve actuators with integral controls, 10–100 NmSeries 6P pneumatic positioner for quarter-turn valves, 3-15 psi signal
TypeMaster station for actuator control and supervisionElectric globe valve actuator with integral controlsElectric globe valve actuator with integral controlspneumatic P/P positioner
Interfaces7” multi-touchscreen, web server, RS-485, Ethernet (RJ45), USB, OPC UA servercontrol inputs DC/AC, potential-free output contacts, fieldbuscontrol inputs DC/AC, potential-free output contacts, fieldbus—
Housingfor 19” rack systemsaluminiumbronze; external screws stainless steeldie-cast aluminium, anodised, powder coated

Request a price and lead time

SIMA² master station for actuator control and supervision. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many devices can one SIMA² station handle?

Up to 4 separate fieldbus networks, each with up to 247 field devices.

Which protocols does the station support?

Modbus RTU or Profibus DP towards the field devices and Modbus RTU and/or Modbus TCP/IP towards the DCS, plus an integral OPC UA server.

Is redundancy available?

Yes. Redundant line and loop topologies are supported, and the system itself can run as a hot standby pair.