SIMA² master station for actuator control and supervision
SIMA² is a master station that controls and supervises actuators and other field devices over standardised fieldbus systems. Each unit takes up to 4 separate networks with up to 247 field devices per network, and has a 7” touchscreen and web server.
- Type
- Master station for actuator control and supervision
- Fieldbus networks
- up to 4 separate per station
- Field devices per network
- up to 247
- Protocols to field devices
- Modbus RTU, Profibus DP
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SIMA² master station sits between the host level and the field level of an installation. It sends operating commands to the actuators, collects their feedback signals and gathers diagnostic data from every connected device in one central function. Commissioning of both the actuators and the fieldbus network is simplified, and actuators can be operated manually from the station's own HMI without a DCS.
One station handles up to 4 separate fieldbus networks, each with up to 247 field devices. Towards the field devices it speaks Modbus RTU or Profibus DP; towards the DCS it uses Modbus RTU and/or Modbus TCP/IP. It also works as a gateway between different communication systems. Single-channel and redundant line and loop topologies are supported, together with hot standby redundancy of the system itself.
On the front and rear panels there are an integral 7” multi-touchscreen, an integrated web server, RS-485, Ethernet (RJ45), USB and an integral OPC UA server. The housing is made for installation in 19” rack systems.
Options include overvoltage protection for RS-485, digital inputs and outputs, alternative housings and project-specific control cabinet versions.
Technical specifications
| Type | Master station for actuator control and supervision |
|---|---|
| Fieldbus networks | up to 4 separate per station |
| Field devices per network | up to 247 |
| Protocols to field devices | Modbus RTU, Profibus DP |
| Protocols to the DCS | Modbus RTU, Modbus TCP/IP |
| Topologies | single-channel and redundant line and loop |
| System redundancy | Hot standby |
| Interfaces | 7” multi-touchscreen, web server, RS-485, Ethernet (RJ45), USB, OPC UA server |
| Housing | for 19” rack systems |
| Options | RS-485 overvoltage protection, digital inputs and outputs, housing options, project-specific control cabinet |
How it compares with similar models
| Parameter | SIMA² master station for actuator control and supervision | SVC/SVCR electric globe valve actuators with integral controls, 10–100 Nm | SVM/SVMR electric globe valve actuators with integral controls, 10–100 Nm | Series 6P pneumatic positioner for quarter-turn valves, 3-15 psi signal |
|---|---|---|---|---|
| Type | Master station for actuator control and supervision | Electric globe valve actuator with integral controls | Electric globe valve actuator with integral controls | pneumatic P/P positioner |
| Interfaces | 7” multi-touchscreen, web server, RS-485, Ethernet (RJ45), USB, OPC UA server | control inputs DC/AC, potential-free output contacts, fieldbus | control inputs DC/AC, potential-free output contacts, fieldbus | — |
| Housing | for 19” rack systems | aluminium | bronze; external screws stainless steel | die-cast aluminium, anodised, powder coated |
Request a price and lead time
SIMA² master station for actuator control and supervision. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many devices can one SIMA² station handle?
Up to 4 separate fieldbus networks, each with up to 247 field devices.
Which protocols does the station support?
Modbus RTU or Profibus DP towards the field devices and Modbus RTU and/or Modbus TCP/IP towards the DCS, plus an integral OPC UA server.
Is redundancy available?
Yes. Redundant line and loop topologies are supported, and the system itself can run as a hot standby pair.