Series 98H Scotch Yoke Hydraulic Actuator, 500–3000 psi (35–207 bar), SIL 3
Modular hydraulic scotch yoke actuator series 98H for quarter-turn valves, including ball valves, butterfly valves, plug valves and dampers. Working pressure is 500–3000 psi (35–207 bar), in double acting or spring return form, and it is suitable for safety functions up to SIL 3.
- Type
- scotch yoke, hydraulic
- Configuration
- DA, DD, SR-CW, SR-CCW
- Torque
- from 187 N·m, sizes 12E2 to 10E4
- Spring end torque
- from 310 N·m
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The 98H drives quarter-turn valves where high torque and fast or frequent operation are needed: emergency shutdown and venting, emergency protection circuits and flow control. It is used in hazardous areas, at remote and offshore sites, and in gas-over-oil circuits. The actuator mounts directly on the valve, and the ISO 5211:2001(E) and MSS SP-101 interface also suits other valves with a matching flange.
The design is modular and the configuration can be changed on site. Modules are centred by precision-machined rings. The yoke is either symmetric or offset. Configurations are double acting with one cylinder (DA) or two cylinders (DD), and spring return closing clockwise (SR-CW) or anticlockwise (SR-CCW). The fail-safe direction can be reversed in the field. Options include an extended stop, hydraulic backup, screw backup, screw backup with gearbox, hydraulic damper, locking and partial stroke testing. Full travel from open to close takes less than one second.
Torque output starts at 187 N·m, and the spring end torque at 310 N·m. Rated torques are 1200 N·m for 12E2 (F12/F07 flanges), 1800 N·m for 18E2 (F12), 4500 N·m for 45E2 (F16/F12), 7300 N·m for 73E2 (F16/F12), 14000 N·m for 14E3 (F25/F16), 24000 N·m for 24E3 (F30/F25), 45000 N·m for 45E3 (F35/F30), and the largest, 10E4, has an F40/F35 flange. Cylinder ports are NPT 1/4 for 32–50 mm cylinders, NPT 1/2 for 63–140 mm and NPT 3/4 for 160–250 mm.
Operating pressure is 500–3000 psi (35–207 bar). The working medium is hydraulic fluid ISO VG 32/46, ISO-L-HV with a flash point above 157 °C, and cleanliness no worse than class 18/16/13 under ISO 4406. Standard temperature runs from -29 to 100 °C, and low-temperature versions go down to -46 °C. The coating is an epoxy base coat of 75–150 micrometres with a polyurethane top coat of 50–75 micrometres.
Testing follows EN 15714-4:2009, and the service life exceeds 1 million cycles under load to EN 15714-3. The enclosure rating is IP67M and IP68 under IEC 60529. The unit carries ATEX and PED certification, and as a Type A device to IEC 61508 it is suitable for SIL 3. Shaft-driven accessories are fitted to VDE 3845 (NAMUR). The design life is about 15 years.
Technical specifications
| Type | scotch yoke, hydraulic |
|---|---|
| Configuration | DA, DD, SR-CW, SR-CCW |
| Torque | from 187 N·m, sizes 12E2 to 10E4 |
| Spring end torque | from 310 N·m |
| Working pressure | 500–3000 psi (35–207 bar) |
| Working medium | hydraulic fluid ISO VG 32/46, ISO-L-HV |
| Temperature (standard) | -29 to 100 °C |
| Temperature (low temperature) | down to -46 °C |
| Mounting interface | ISO 5211:2001(E), MSS SP-101 |
| Accessory mounting | VDE 3845 (NAMUR) |
| Ingress protection | IP67M, IP68 per IEC 60529 |
| Testing | EN 15714-4:2009 |
| Certification | ATEX, PED, SIL 3 |
| Travel time | under 1 second |
| Cylinder ports | NPT 1/4, 1/2, 3/4 |
| Coating | epoxy 75–150 micrometres, polyurethane 50–75 micrometres |
Part numbers
Show all part numbers (8)
12E2, 18E2, 45E2, 73E2, 14E3, 24E3, 45E3, 10E4
Request a price and lead time
Series 98H Scotch Yoke Hydraulic Actuator, 500–3000 psi (35–207 bar), SIL 3. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Is the 98H suitable for safety instrumented systems?
Yes. It is a Type A device to IEC 61508 and is suitable for SIL 3. A partial stroke test option is available.
Which fluid is needed for operation?
Hydraulic fluid ISO VG 32/46, ISO-L-HV, with a flash point above 157 °C and cleanliness no worse than 18/16/13 under ISO 4406.
Can the fail-safe direction be changed on site?
Yes. In the spring return version the direction, SR-CW or SR-CCW, is changed in the field, as the design is modular.
Similar equipment from other manufacturers