Series 98EH Electro-Hydraulic Actuator, 132 to 97515 Nm

The 98EH drives valves hydraulically from a self-contained power unit with an electric pump. The hydraulic circuit is closed, so it releases nothing to the atmosphere, and the actuator supports on/off and modulating duty. Output torque runs from 132 to 97515 Nm, with a working pressure of 10 to 207 bar.

Type
electro-hydraulic actuator with self-contained hydraulic power unit
Output torque
132 to 97515 Nm
Control signals
12, 24 or 48 VDC, 120 or 220 VAC, 4 to 20 mA, 0 to 10 VDC, network protocols
Power supply
12, 24 or 48 VDC, 120 or 220 VAC, 480 V three-phase, 50 to 60 Hz, solar or wind charged power packs

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 98EH series automates pipeline valves in demanding duty at power plants, mining and mineral processing sites, LNG facilities, gas and oil pipelines, water and wastewater systems, oil and gas fields, and pulp and paper mills. It can operate as an on/off valve with electrical fail-safe action, as a control valve in modulating service, and in ESD and SIS applications that require a SIL rating.

The hydraulic power unit is built into the actuator and is either mounted directly on the actuator body or supplied on its own floor stand to power one or several valve cylinders. The hydraulic circuit is closed, which avoids the exhaust associated with pneumatic and gas-operated actuators. Hydraulics give large forces and torques, quick stroking and precise, repeatable positioning.

Output torque ranges from 132 to 97515 Nm, and the maximum allowable operating pressure runs from 10 to 207 bar. The actuator is available double-acting or spring-return, with a fail position of fail freeze, fail last, fail open or fail close achieved by spring or accumulator energy. Other features include manual override for loss of power, line-break protection, partial stroke testing (PST), local and remote diagnostics and control, and status alarms.

Power can be 12, 24 or 48 VDC, 120 or 220 VAC, or 480 V three-phase at 50 to 60 Hz. Remote sites without a grid can use power packs charged by solar panels or a wind turbine. Control signals can be 4 to 20 mA, 0 to 10 VDC, discrete voltages or network protocols, and the hydraulic power unit can be located away from the actuator. The working temperature range is -46 to 100 °C. The housing is either weatherproof or explosion proof, with UL, FM, CSA and ATEX certification. Mounting follows ISO 5211:2001(E) and MSS SP-101-1989, and testing follows EN 15714-4:2009. It suits rotary, linear, multi-turn and damper valves, including retrofits in place.

Technical specifications

Typeelectro-hydraulic actuator with self-contained hydraulic power unit
Output torque132 to 97515 Nm
Control signals12, 24 or 48 VDC, 120 or 220 VAC, 4 to 20 mA, 0 to 10 VDC, network protocols
Power supply12, 24 or 48 VDC, 120 or 220 VAC, 480 V three-phase, 50 to 60 Hz, solar or wind charged power packs
Maximum allowable operating pressure150 to 3000 psi (10 to 207 bar)
Temperature range-46 to 100 °C (-50 to 212 °F)
Housingweatherproof or explosion proof
MountingISO 5211:2001(E), MSS SP-101-1989
Testing standardEN 15714-4:2009
Operating modeon/off, modulating
Actiondouble-acting or spring return
Fail positionfail freeze, fail last, fail open, fail close
Compatible valvesrotary, linear, multi-turn, dampers
CertificationsUL, FM, CSA, ATEX

Part numbers

Show all part numbers (1)

Series 98EH

Request a price and lead time

Series 98EH Electro-Hydraulic Actuator, 132 to 97515 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Is an external hydraulic supply needed?

No, the actuator has its own hydraulic power unit, which can be mounted on the actuator or on a separate stand that serves several cylinders.

How does the actuator move to its fail position?

A spring or accumulator energy drives it to the chosen position: fail freeze, fail last, fail open or fail close.

Can the actuator be used at remote sites without a mains supply?

Yes, the hydraulic unit can be powered by packs charged from solar panels or a wind turbine, and 12, 24 or 48 VDC supplies are also available.

Similar equipment from other manufacturers