PFA Lined Butterfly Valve Acris Series 24/25, DN 50–600

The Acris Series 24/25 valves have a body and disc fully lined with PFA, and a double-sided seal gives zero leakage in both directions. They suit corrosive and very clean media such as chlorine, brine and sulphuric acid, as well as alkaline solutions and ultrapure water.

Sizes
NPS 2–24 | DN 50–600
Operating temperature
-20…320 °F | -29…160 °C
Pressure DN 50–150
up to 16 bar (232 psi)
Pressure DN 200–600
up to 10 bar (150 psi)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Both the body and the disc are lined throughout with PFA. The spherically cast liner and the matching disc form a tight seal that works in both directions. This lining resists corrosion, permeation and microbial contamination. The seat is pressed evenly, so the energiser covers its full 360° width. The stem is sealed by a constant-preload system, the PFA lining extends onto the shaft, and the flange seal is preloaded as well.

The body is ductile iron to ASTM A395 and comes in two halves, supplied either as a wafer for fitting between flanges (Series 24) or as a lug pattern (Series 25). Between DN 50 and 300 the disc and stem are 17-4 stainless steel, over-moulded with PFA. For DN 350 to 600 the stem is 17-4 steel while the disc is high-strength steel, also over-moulded with PFA. The seat energiser is silicone or Viton™, and the body bolts are 18-8 stainless steel or A193 Gr B7.

The range covers NPS 2 to 24, equivalent to DN 50 to 600, and the operating temperature runs from -29 to 160 °C. Maximum allowable pressure is 16 bar (232 psi) for DN 50 to 150 and 10 bar (150 psi) for DN 200 to 600. Vacuum service is possible down to 1.03 x 10⁻² torr (0.0002 psia).

The design follows MSS SP-155 and MSS SP-67, and tightness is verified against API 598 and ISO 5208. Face-to-face dimensions meet API 609, ISO 5752 and EN 558 series 20. The flanges can be drilled to ASME B16.5 CL150, ASME B16.1 CL125, PN10, PN16 or JIS 10K, and the top flange for an actuator follows ISO 5211. The valves are SIL 3 certified, with fugitive emissions confirmed to ISO 15848-1.

Typical applications include chemical and petrochemical plant, chlor-alkali production, ion exchange resin systems, reverse osmosis make-up water, semiconductor manufacturing, ultrafiltration, ultrapure piping, UV systems, vacuum lines and wastewater treatment. The media handled include brine, bromine, alkalis, wet and dry chlorine, hydrochloric acid, organic solvents, phosphate fertilisers, strong oxidisers, sulphuric acid, ultrapure water and viscous liquids.

Technical specifications

SizesNPS 2–24 | DN 50–600
Operating temperature-20…320 °F | -29…160 °C
Pressure DN 50–150up to 16 bar (232 psi)
Pressure DN 200–600up to 10 bar (150 psi)
Vacuumup to 0.0002 psia | 1.03 x 10⁻² torr
Body type2-piece, wafer (Series 24), lug (Series 25)
Tightnesszero leakage
Bodyductile iron ASTM A395
LinerPFA
Disc and stem DN 50–30017-4 stainless steel, over-moulded with PFA
Disc and stem DN 350–60017-4 stainless steel stem, high-strength steel disc, over-moulded with PFA
Seat energisersilicone or Viton™
DesignMSS SP-155, MSS SP-67
TestingAPI 598, ISO 5208
Face to faceAPI 609, ISO 5752, EN 558 series 20
FlangesASME B16.5 CL150, ASME B16.1 CL125, PN10, PN16, JIS 10K
Top flangeISO 5211
CertificationSIL 3, ISO 15848-1

Part numbers

Show all part numbers (1)

2X-XXXX-110XX-XXX

Request a price and lead time

PFA Lined Butterfly Valve Acris Series 24/25, DN 50–600. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the maximum pressure for DN 200 to 600 valves?

Up to 10 bar (150 psi). For DN 50 to 150 the allowable pressure is up to 16 bar (232 psi).

How do Series 24 and Series 25 differ?

Series 24 has a wafer body that fits between flanges, while Series 25 has a lug body. Both versions have a PFA lining and cover DN 50 to 600.

Can an actuator be mounted on the valve?

Yes, the top flange is built to ISO 5211 for mounting an actuator.