Anti-Cavitation Valves 78400 and 18400 (LincolnLog), 1-12 in, ANSI 600-2500, API 6A 15K
Valves of the 78400 angle style and the 18400 globe style handle liquids that face a large pressure drop, without cavitation. A multi-stage axial flow trim spreads the drop along the plug, giving a turndown ratio up to 150 to 1 and a total drop above 8000 psi (550 bar).
- Body type
- 18400 globe; 78400 angle; cast or forged
- Size
- 1-12 in (25-300 mm)
- Connections
- flanged ANSI 600-2500, UNI-DIN 100-400; BW, SW; RF, RTJ, threaded
- API 6A rating
- 10K or 15K psi, sizes 1-6 in
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Operators fit this valve where liquid has to be throttled down from high pressure: pump recirculation, letdown of high-pressure liquid, hydroprocessing and cracking units, high-pressure separators, produced water injection, rich amine lines and wellhead chokes. In power plants it serves boiler feedwater start-up lines and high-pressure spraywater control, as well as heat recovery steam generator and balance-of-plant duties. Refining, midstream and upstream oil and gas, and pulp and paper plants also use it.
Flow passes along an axial path that winds along the plug, and the stages throttle together at every stroke, so the drop at each stage stays limited. That limit is what keeps cavitation and trim damage out of the picture. Trims come with 3, 4, 6, 8 and 10 stages. The recommended drop per stage is 800 psi (55 bar) in continuous service and 1000 psi (69 bar) intermittently. Characteristics are linear or modified linear.
The plug is continuously guided at the top, with the liner acting as the main guide. The stem is hardened 440C steel or another hardened grade, and it runs in PTFE packing. On the two smallest sizes, the seat is built into the liner and can be swapped quickly. Flow goes to open as standard and to close on request. A protected soft seat for 2 in to 8 in (DN 50 to DN 200) gives Class VI shut-off.
Bodies are cast or forged in carbon, stainless and chrome-moly steels, and can be specified in F6NM, F51, F55 and Inconel 718. Sizes run from 1 in to 12 in (25 to 300 mm). Flanged connections follow ANSI 600 to 2500 and UNI-DIN 100 to 400, with butt or socket weld, and RF, RTJ or threaded ends also available. Metal seat temperatures run from -20 °F (-29 °C) to 600 °F (316 °C), and soft seats to 450 °F (232 °C). NACE and cryogenic material variants are offered.
The forged API 6A series, rated 10K or 15K psi in sizes 1 in to 6 in, uses unbalanced assembly 18489 for the 1 in size and balanced assembly 18483 for 1.5 in to 6 in. Materials follow NACE MR0175, ISO 15156 and MR0103, and the valves are built under the Pressure Equipment Directive. Actuators are pneumatic diaphragm models 87 and 88, piston models 51, 52 and 53, or electrohydraulic types, and SVI II AP HART and SVI FF Foundation Fieldbus positioners complete the control package.
Technical specifications
| Body type | 18400 globe; 78400 angle; cast or forged |
|---|---|
| Size | 1-12 in (25-300 mm) |
| Connections | flanged ANSI 600-2500, UNI-DIN 100-400; BW, SW; RF, RTJ, threaded |
| API 6A rating | 10K or 15K psi, sizes 1-6 in |
| Number of stages | 3, 4, 6, 8, 10 |
| Drop per stage | 800 psi (55 bar) continuous; 1000 psi (69 bar) intermittent |
| Maximum pressure drop | above 8000 psi (550 bar) |
| Turndown ratio | up to 150:1 |
| Characteristic | linear, modified linear |
| Seat leakage class | IV, V, VI per ANSI 70.2; MSS-SP-61; IEC 60534-4 |
| Temperature, metal seat | -20 °F (-29 °C) to 600 °F (316 °C) |
| Temperature, soft seat | -20 °F (-29 °C) to 450 °F (232 °C) |
| Body materials | carbon steel, stainless steel, chrome-moly, F6NM, F51, F55, Inconel 718 |
| Stem / packing | 440C / PTFE |
| Actuators | diaphragm 87/88; piston 51/52/53; electrohydraulic |
| Positioners | SVI II AP (HART), SVI FF (Foundation Fieldbus) |
| Standards | API 6A; NACE MR0175/ISO 15156; NACE MR0103; PED |
Part numbers
Show all part numbers (4)
78400, 18400, 18489, 18483
Request a price and lead time
Anti-Cavitation Valves 78400 and 18400 (LincolnLog), 1-12 in, ANSI 600-2500, API 6A 15K. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do the 78400 and 18400 series differ?
The 78400 has an angle body and the 18400 a globe body, and both use the same LincolnLog trim. Each is available in cast or forged versions.
What pressure drop can the valve take?
A total drop above 8000 psi (550 bar), with 800 psi (55 bar) per stage in continuous service. The number of stages is chosen from 3 to 10.
Is there an API 6A version for wellheads?
Yes. The forged API 6A series is rated 10K or 15K psi in sizes 1 to 6 in, with 18489 for 1 in and 18483 for 1.5 to 6 in.