Ti29 Industrial Thermal Imager with 280x210 Array, −20…+600 °C, 9/60 Hz
The middle model of the Ti32/Ti29/Ti27 family, a handheld imager for maintenance teams in plants and commercial buildings. It picks out hot joints in switchgear, failing bearings, blocked steam traps, damaged refractory and tank levels, and blends every infrared shot with a visible-light photo.
- IR detector
- uncooled microbolometer 280x210 (58,800 pixels)
- Spectral band
- 7.5–14 μm
- Measurement range
- −20 to +600 °C (calibrated from −10 °C)
- Accuracy
- ±2 °C or 2%
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
On the electrical side, the typical finds are unbalanced loads, overloaded circuits, wiring mistakes and failing components. Process engineers use the same camera on refractory linings, tank and vessel levels, steam systems, traps, pipes and valves, and mechanical fitters on motors and drives.
The detector is a 280x210 uncooled focal plane array, 58,800 pixels in all, working in the 7.5–14 μm long-wave band. NETD is 50 mK (0.05 °C at a 30 °C target). Readings span −20 °C to +600 °C, with calibration guaranteed only above −10 °C, and the tolerance is ±2 °C or 2%, taking the larger figure. Buyers choose between a 9 Hz and a 60 Hz frame rate. Within the family, the Ti27 has 240x180 pixels and the Ti32 320x240.
A 2.0 megapixel visible camera is parallax-corrected to the infrared image, and picture-in-picture or full-screen modes each offer three blending levels. Focusing is manual and can be done with one hand. The standard lens gives a 23 × 17° field with 1.43 mRad IFOV and focuses from 15 cm. Interchangeable optics extend this: a 11.5 × 8.7° telephoto at 0.72 mRad (from 45 cm) and a 46 × 34° wide-angle at 2.86 mRad (from 7.5 cm).
Images appear on a 9.1 cm (3.7 in) VGA 640x480 backlit LCD. Eight palettes, auto or manual level and span (minimum span 2.5 °C manual, 5 °C auto) and a high-temperature colour alarm are built in. Up to 60 s of voice notes can be attached to each image. Files save as .bmp, .jpeg or fully radiometric .is2, and analysis and reporting software is supplied.
Two lithium-ion packs with five-segment charge gauges each last four hours or more at 50% screen brightness and recharge in 2.5 hours, in the two-bay mains charger (110–220 V AC, 50/60 Hz) or in the camera; a 12 V vehicle adaptor is optional. The IP54 body weighs 1.05 kg, measures 27.7 x 12.2 x 17.0 cm and survives a 6.5 ft drop. It operates from −10 °C to +50 °C.
Technical specifications
| IR detector | uncooled microbolometer 280x210 (58,800 pixels) |
|---|---|
| Spectral band | 7.5–14 μm |
| Measurement range | −20 to +600 °C (calibrated from −10 °C) |
| Accuracy | ±2 °C or 2% |
| NETD | ≤ 0.05 °C at 30 °C (50 mK) |
| Frame rate | 9 Hz / 60 Hz |
| Standard lens | 23 × 17°, IFOV 1.43 mRad, focus from 15 cm |
| Telephoto / wide-angle | 11.5 × 8.7° (0.72 mRad) / 46 × 34° (2.86 mRad) |
| Visible camera | 2.0 MP |
| Display | 9.1 cm, VGA 640x480 |
| Batteries | 2 Li-ion packs, 4+ h each, 2.5 h charge |
| Protection | IP54 |
| Weight | 1.05 kg |
| Operating temperature | −10 to +50 °C |
Request a price and lead time
Ti29 Industrial Thermal Imager with 280x210 Array, −20…+600 °C, 9/60 Hz. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How does the Ti29 differ from the Ti27 and Ti32?
Mainly in detector resolution: 240x180 on the Ti27, 280x210 on the Ti29 and 320x240 on the Ti32.
Which lenses are available?
Besides the standard 23 × 17° lens there is a 11.5 × 8.7° telephoto and a 46 × 34° wide-angle that focuses from 7.5 cm.
What file formats does it save?
Non-radiometric .bmp or .jpeg, and fully radiometric .is2 for analysis in the supplied software.
Similar equipment from other manufacturers