International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

UltraVac Solid Dielectric Vacuum Capacitor Switch, Single-Phase, 15 to 24 kV, 200 A and 400 A

UltraVac switches have a vacuum chamber in a cycloaliphatic epoxy solid dielectric, and they switch capacitor banks used for reactive power compensation. The range covers 110, 125 and 150 kV BIL insulation levels, carries a re-strike class of C2 and offers solenoid or motor drives at 120 VAC.

Type
vacuum capacitor switch in solid dielectric
Phases
single-phase
Rated current
200 A / 400 A
Voltage classes
15, 20, 22, 24 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

UltraVac is the most flexible capacitor switch line in the manufacturer's range and suits a wide variety of switching arrangements. The vacuum interrupter sits in a solid cycloaliphatic epoxy dielectric. The switch requires no maintenance, offers high dielectric strength, a long service life and simple installation.

The switch is single-phase with a 120 VAC control circuit. Depending on the version, a solenoid or motor drive is fitted. The kit includes a manual handle, a 5-pin socket for the control cable, a NEMA-type pole bracket and 2 protective covers against animals. A separate 5-pin auxiliary socket is standard, and auxiliary contacts are ordered separately. The switch is rated re-strike class C2, and its performance exceeds ANSI requirements.

The series covers 110, 125 and 150 kV BIL insulation levels. The 200 A versions span the 15 kV, 20 kV and 24 kV classes, and the 400 A versions the 15 kV and 22 kV classes. Bushing creepage distances are 11.5, 18, 27 or 33 in. Compact versions carry the letter C at the end of the part number and have shorter bushings. For example, 33247102C is rated 15 kV, 110 kV BIL and 200 A with a solenoid drive and an 18 in creepage distance. The 33247102 has 33 in bushings with the same ratings, and both measure 15.000 in x 17.750 in x 33.000 in, while the 33247102 weighs 51 lb.

The 33257102C, 33257202C and 33257402C 400 A versions are compact, with 18 in creepage and solenoid drives. Motor-driven versions are available, notably at 20 kV and 24 kV.

The switch is installed on an overhead line pole using a NEMA bracket, and the control cable from the capacitor bank controller connects through the 5-pin socket. The bank can be switched automatically from the controller or by hand with the handle. The interruption type is listed as cycloaliphatic epoxy, and the switch type is vacuum in solid dielectric.

Technical specifications

Typevacuum capacitor switch in solid dielectric
Phasessingle-phase
Rated current200 A / 400 A
Voltage classes15, 20, 22, 24 kV
Insulation level110, 125, 150 kV BIL
Bushing creepage distance11.5, 18, 27, 33 in
Drivesolenoid or motor, 120 VAC
Insulationcycloaliphatic epoxy
Re-strike classC2
Dimensions 33247102C / 3324710215.000 in x 17.750 in x 33.000 in
Weight 3324710251 lb
Supplied withmanual handle, 5-pin socket, NEMA bracket, 2 protective covers
Optionsauxiliary contacts

Part numbers

Show all part numbers (17)

33247102C, 33247102, 33247402, 33247202C, 33247202, 33247501, 33247501C, 33247402C, 33247601C, 33247601, 33248401, 33248401C, 33249401, 33249401C, 33257102C, 33257202C, 33257402C

Request a price and lead time

UltraVac Solid Dielectric Vacuum Capacitor Switch, Single-Phase, 15 to 24 kV, 200 A and 400 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What does the letter C in the part number mean?

The letter C denotes a compact version with shorter bushings, mostly with an 18 in creepage distance, as in 33247102C.

Which versions are rated 400 A?

33257102C at 15 kV, 110 kV BIL, 33257202C at 22 kV, 125 kV BIL and 33257402C at 22 kV, 150 kV BIL, all compact with solenoid drives.

Can auxiliary contacts be added?

The 5-pin auxiliary socket is standard, and auxiliary contacts are available as an option to be ordered separately.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides