International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Liberty 3GR Three-Phase Ganged Recloser, 15, 27 and 38 kV, up to 800 A, Solid Dielectric

The Liberty 3GR ganged recloser switches all three phases together and is intended to interrupt three-phase faults on overhead lines of the 15, 27 and 38 kV classes. It has vacuum interrupters in solid dielectric, six built-in voltage sensors and three current sensors, and it connects to the controller through a single 32-pin connector.

Type
three-phase ganged recloser, overhead, solid dielectric
Series
Liberty 3GR
Rated voltage
up to 15 kV, up to 27 kV, up to 38 kV
Insulation level
110 kV BIL, 150 kV BIL, 170 kV BIL

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The recloser is supplied as a package ready for site installation: the controller, cables and switching device are assembled, configured, matched and tested together to the customer's requirements. The contents of the package are adapted to each application. The phases are ganged and switched together, and the device is rated to interrupt three-phase faults on medium-voltage distribution networks.

Interruption is by vacuum, with the chambers in solid dielectric. The manufacturer classifies the device as an overhead switching apparatus with solid dielectric insulation. Six voltage sensors and three current sensors are built in, and the measurement and control circuits are brought out to a single 32-pin connector. The body carries a position flag, a mechanical operation counter and a manual operating handle with interlock.

Three ratings are offered. The 15 kV version is rated 630 A with a 110 kV BIL. The 27 kV version is rated 800 A with a 150 kV BIL and a 16 kA interrupting current, and the 38 kV version is rated 800 A with a 170 kV BIL and a 16 kA interrupting current. The rated frequency is 50/60 Hz, so the device suits networks operating at either frequency.

Three mounting options are available: side, centre and substation structure. Control transformers, surge arresters, animal guards and power and control cables can be supplied as extras. A terminal option is available for the 27 kV version.

The recloser connects to the controller with a single cable through the 32-pin connector. The position flag shows the contact position, and the mechanical counter records the number of operations. The manual handle is used for local operation and to lock the device.

Technical specifications

Typethree-phase ganged recloser, overhead, solid dielectric
SeriesLiberty 3GR
Rated voltageup to 15 kV, up to 27 kV, up to 38 kV
Insulation level110 kV BIL, 150 kV BIL, 170 kV BIL
Rated current630 A (15 kV), 800 A (27 and 38 kV)
Interrupting current16 kA (27 and 38 kV)
Frequency50/60 Hz
Arc interruptionvacuum interrupters in solid dielectric
Built-in sensors6 voltage sensors, 3 current sensors
Control connectorone 32-pin
Indicationposition flag, mechanical counter
Manual operationoperating handle with interlock
Mountingside, centre, substation structure
Optionscontrol power transformers, surge arresters, animal guards, power and control cables

Request a price and lead time

Liberty 3GR Three-Phase Ganged Recloser, 15, 27 and 38 kV, up to 800 A, Solid Dielectric. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sensors are built into the recloser?

Six voltage sensors and three current sensors. Their signals are brought to the controller through a single 32-pin connector.

How does the 38 kV version differ?

The 38 kV version has a 170 kV BIL insulation level, a rated current of 800 A and a 16 kA interrupting current.

Can the recloser be locked on site?

Yes. The body has a manual operating handle with interlock, and the position flag shows the contact position.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00