Liberty 3GR Three-Phase Ganged Recloser, 15, 27 and 38 kV, up to 800 A, Solid Dielectric
The Liberty 3GR ganged recloser switches all three phases together and is intended to interrupt three-phase faults on overhead lines of the 15, 27 and 38 kV classes. It has vacuum interrupters in solid dielectric, six built-in voltage sensors and three current sensors, and it connects to the controller through a single 32-pin connector.
- Type
- three-phase ganged recloser, overhead, solid dielectric
- Series
- Liberty 3GR
- Rated voltage
- up to 15 kV, up to 27 kV, up to 38 kV
- Insulation level
- 110 kV BIL, 150 kV BIL, 170 kV BIL
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The recloser is supplied as a package ready for site installation: the controller, cables and switching device are assembled, configured, matched and tested together to the customer's requirements. The contents of the package are adapted to each application. The phases are ganged and switched together, and the device is rated to interrupt three-phase faults on medium-voltage distribution networks.
Interruption is by vacuum, with the chambers in solid dielectric. The manufacturer classifies the device as an overhead switching apparatus with solid dielectric insulation. Six voltage sensors and three current sensors are built in, and the measurement and control circuits are brought out to a single 32-pin connector. The body carries a position flag, a mechanical operation counter and a manual operating handle with interlock.
Three ratings are offered. The 15 kV version is rated 630 A with a 110 kV BIL. The 27 kV version is rated 800 A with a 150 kV BIL and a 16 kA interrupting current, and the 38 kV version is rated 800 A with a 170 kV BIL and a 16 kA interrupting current. The rated frequency is 50/60 Hz, so the device suits networks operating at either frequency.
Three mounting options are available: side, centre and substation structure. Control transformers, surge arresters, animal guards and power and control cables can be supplied as extras. A terminal option is available for the 27 kV version.
The recloser connects to the controller with a single cable through the 32-pin connector. The position flag shows the contact position, and the mechanical counter records the number of operations. The manual handle is used for local operation and to lock the device.
Technical specifications
| Type | three-phase ganged recloser, overhead, solid dielectric |
|---|---|
| Series | Liberty 3GR |
| Rated voltage | up to 15 kV, up to 27 kV, up to 38 kV |
| Insulation level | 110 kV BIL, 150 kV BIL, 170 kV BIL |
| Rated current | 630 A (15 kV), 800 A (27 and 38 kV) |
| Interrupting current | 16 kA (27 and 38 kV) |
| Frequency | 50/60 Hz |
| Arc interruption | vacuum interrupters in solid dielectric |
| Built-in sensors | 6 voltage sensors, 3 current sensors |
| Control connector | one 32-pin |
| Indication | position flag, mechanical counter |
| Manual operation | operating handle with interlock |
| Mounting | side, centre, substation structure |
| Options | control power transformers, surge arresters, animal guards, power and control cables |
Request a price and lead time
Liberty 3GR Three-Phase Ganged Recloser, 15, 27 and 38 kV, up to 800 A, Solid Dielectric. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which sensors are built into the recloser?
Six voltage sensors and three current sensors. Their signals are brought to the controller through a single 32-pin connector.
How does the 38 kV version differ?
The 38 kV version has a 170 kV BIL insulation level, a rated current of 800 A and a 16 kA interrupting current.
Can the recloser be locked on site?
Yes. The body has a manual operating handle with interlock, and the position flag shows the contact position.