Liberty 3GR three-phase ganged recloser 27 kV, 800 A, 16 kA, BIL 150 kV
Liberty 3GR is a three-phase recloser with three vacuum switching modules operated by a common ganged mechanism in one housing, for pole or substation mounting. It has solid insulation, six built-in voltage sensors and three current sensors, and is supplied assembled with a controller and cables.
- Type
- three-phase recloser with ganged operation
- Series
- Liberty 3GR
- Rated voltage
- up to 27 kV
- BIL
- 150 kV
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The Liberty 3GR recloser is designed to trip and automatically reclose three-phase distribution lines during short circuits. It performs sectionalising and switching functions in distribution automation schemes. The rated voltage is up to 27 kV, the rated current 800 A, the breaking current 16 kA, the BIL 150 kV and the frequency 50/60 Hz.
Structurally the unit consists of three vacuum breakers with a common mechanical drive in one housing. The arc quenching chambers are vacuum-type, within solid insulation. The housing is welded and riveted stainless steel, zinc-primed and finished in ANSI 70 colour for mechanical strength and corrosion resistance.
Six voltage sensors and three current sensors are built in, and their signals reach the controller through a single 32-pin connector. A semaphore indicator shows the contact position and a mechanical counter records operations. For manual control and locking there is a trip handle with a locking latch.
The unit is supplied as a ready-to-install kit, in which the controller, cables and switching device are assembled, configured and tested together. Items ordered separately include control supply transformers, surge arresters, animal protection, and power and control cables. Mounting is possible in a central or side position on a pole or on a substation structure, with a choice of terminals. The configuration is agreed for each point in the network. When selecting, check the network voltage, the calculated load current up to 800 A and the short-circuit current at the point of installation, which must not exceed 16 kA.
Technical specifications
| Type | three-phase recloser with ganged operation |
|---|---|
| Series | Liberty 3GR |
| Rated voltage | up to 27 kV |
| BIL | 150 kV |
| Rated current | 800 A |
| Breaking current | 16 kA |
| Frequency | 50/60 Hz |
| Arc quenching | vacuum, solid insulation |
| Sensors | 6 voltage sensors, 3 current sensors |
| Control connector | one, 32-pin |
| Housing | stainless steel, zinc primer, ANSI 70 paint |
| Indication | semaphore, mechanical operations counter |
| Manual operation | trip handle with locking |
| Mounting | central, side, substation |
| Options | control supply transformers, surge arresters, animal protection, cables |
Request a price and lead time
Liberty 3GR three-phase ganged recloser 27 kV, 800 A, 16 kA, BIL 150 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which sensors are built into the recloser?
Six voltage sensors and three current sensors. Their signals are brought out to the controller through a single 32-pin connector.
How is the recloser installed?
On a pole in a central or side position, or on a substation structure. The unit is supplied with a controller and cables, configured and tested.
Can the recloser be tripped by hand?
Yes, there is a manual trip handle with locking, and a semaphore shows the contact position.